De-scaling
The red indicator light will be illuminated when the
boiler gets too hot and needs to be cleaned and/
or descaled.
This appliance should be cleaned and descaled
frequently. To keep this appliance in optimum
condition and to ensure its operation, it is crucial
that you descale the appliance on a regular basis.
Depending on the hardness of the water and the
frequency of use, you need to repeat the following
procedure regularly.
To descale use a descaling agent that is suitable for
water boiler. You can also use pure lemon juice, cit-
ric acid or cleaning vinegar as a de-scaling agent.
To ensure the proper mixture, read the instructions
supplied with the agent. For pure lemon juice or
cleaning vinegar the general mixture applies of 1/3
cleaning vinegar or lemon juice to 2/3 water.

Troubleshooting

If the appliance does function properly, please check the below table for the solution. If you are still unable to
solve the problem, please contact the supplier/service provider.
EN
Defect
Boiler does not work at
all.
Boiler switches off
automatically.
Boiler does not reach the
selected temperature.
Technical specification
Item no.
Operating voltage and
frequency
Rated input power
Protection class
Waterproof class
Colour
Capacity
Dimensions
Remark: Technical specification is subjected to change without prior notification.
6
Problem
Cause
Neither red light
No mains voltage.
nor orange light is
illuminated.
The red light is
illuminated.
Orange light is keep
Thermostat does not
illuminating.
work.
211410
950W
Stainless steel
10L
307*330*(H)450mm
1. Pour the solution in the boiler to maximum the
"MAX" level.
2. Wait to allow the solution to loosen the build-up.
3. Rub lightly and gently with a brush with soft bris-
tles.
4. Drain off the dirty water.
5. Repeat steps 1~4 until build-up has been re-
moved.
6. Use a dry cloth to wipe the solution away.
7. When you drain off dirty water, leave the tap open
and rinse the boiler with clean water till taste
and smell are completely gone.
8. Now you can use the boiler again.
Note: Warranty is void if failure to de-scale regu-
larly leads to reduced functioning or failure of the
appliance.
1. Boiler has exceeded
maximum safety
limits.
2. Fuse does not work
211458
211427
220-240V~50/60Hz
Class I
IPX 1
Black
Stainless steel
Possible solution
Check the electrical
connections.
1. Once it has cooled off,
the boiler will switch on
again automatically.
2. Contact your supplier.
Contact your supplier.
211465
1650W
Black
18L
357*380*(H)502mm

Werbung