Herunterladen Inhalt Inhalt Diese Seite drucken

Cardin Elettronica SL Serie Bedienungsanleitung Seite 66

Vorschau ausblenden Andere Handbücher für SL Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 134
5s) Low battery
• Press PROG/OK to scroll between the available choices:
- STOP (blocks the gate)
- GUARANTEE OPEN. (guarantee the opening of the gate before it loses power)
- GUARANTEE CLOSE (guarantee the closing of the gate before it loses power)
• Press the arrow button
and move to the next parameter.
This option determines the behaviour of the programmer when the battery is almost flat.
5t) Master/Slave
• Press PROG/OK to scroll between the available choices:
- MASTER MODE (master motor in an installation with two sliding gates)
- SLAVE MODE (slave motor in an installation with two sliding gates)
- OFF (setting for installations with a single motor - default setting)
• Press the arrow button
and move to the next parameter.
The double motor function requires a series of particular settings, see paragraph
5u) Forced closing
• Press PROG/OK to scroll between the available choices:
- ON - OFF
• Press the arrow button
• Press PROG/OK to return to the main menu.
It the parameter is set to 'ON' and the gate is completely closed, the programmer will force a closing direction movement
after 10 seconds of pre-flashing has elapsed.
to confirm the choice eg. STOP. The programmer will save the choice
to confirm the choice eg. OFF. The programmer will save the choice
to save the choice and move to
MASTER-SLAVE FUNCTION
.
EXIT
66
5s) Low battery
CP GATE OPEN
STOP
LC/CH2 OUTPUT
RADIO CHANNEL
LOW BATTERY
STOP
5s) Master/Slave
LC/CH2 OUTPUT
RADIO CHANNEL
LOW BATTERY
STOP
MASTER/SLAVE
MASTER MODE
.
5u) Forced closing
MEMORADIO
ON
LC/CH2 OUTPUT
RADIO CHANNEL
FORCED CLOSING
OFF

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bl serieHl serieSli serieBli serie

Inhaltsverzeichnis