Electronic control unit for dc motors with an incorporated radio receiver card, which allows the memorisation of 300 user codes for the
series S4XX or 1000 user codes for the series S500 The decoder uses rolling codes and the reception frequency is 433.92 MHz with an
S449 or S504 radio frequency module and 868 MHz with an S486 or S508 radio frequency module.
The motor rotation speed is electronically controlled, starting slowly and increasing in speed; the speed is reduced as it nears the travel
limit so as to enable a controlled smooth stop.
Programming is carried out using
travel distance. The intervention of the anticrush/antidrag sensor during the closing and opening stages causes travel direction inversion.
Attention! There is no 230 Vac contact on any part of the electronic card: only low voltage safety current is available. In conformity
with the electrical safety standards it is forbidden to connect binding posts 9 and 10 directly to a circuit that receives power
greater than 30 Vac/dc.
• For the correct operation of the programmer the incorporated batteries must be in good condition: the programmer will lose the position
of the gate in case of blackouts when the batteries are flat and the alarm indication will appear on the display. Check the good working
order of the batteries every six months (see page 87 'Battery check').
• The controlled load output (binding post 15) is aimed at reducing battery power consumption (if they are installed) during blackouts;
photocells and other safety devices should be connected to this output.
• When a command is received, via radio or via wire, the electronic programmer routes voltage to the CTRL 24 Vdc output. It then
evaluates the state of the safety devices and if they are at rest it will activate the motor.
• Connecting devices to the 'controlled output' contact also allows you to carry out the autotest function (enabled using 'TEST FI' and
'TEST FS' in the 'OPTIONS') and check that the safety devices are functioning correctly.
• The power cable must be made of polychloroprene in conformity with the standard 60245 IEC 57 (e.g. 3 x 1.5 mm
• The cable may only be replaced by qualified technicians.
• Don't use cables with aluminium conductors; don't solder the ends of cables which are to be inserted into the binding posts; use cables
marked T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both the wire and the insulating sheath are tightly fastened.
IMPORTANT REMARKS - IMPORTANT REMARKS
PROG/OK
buttons and allows you to set the system, the current sensor and the entire gate
47
H05RN-F).