4b) Current sensor
• Press PROG/OK to scroll between the available choices:
- Level 1 = motor electrical input + 2 amps;
- Level 2 = motor electrical input + 3 amps;
- Level 4 = motor electrical input + 5 amps;
Press the arrow button
parameter.
The programmer checks the electrical input to the motor, detecting any eventual increase in effort above
the normal operating limits and intervenes as an additional safety device. When the sensor intervenes the
gate will automatically invert for 10 cm, both in the closing as well as the opening direction, to free the ob-
stacle it will then stop for 3 minutes and then continue moving in the original direction after a 10-second
pre-flashing period has elapsed.
4b) Current sensor
• Press PROG/OK to scroll between the available choices:
- Level 1 = motor electrical input + 2 amps;
- Level 2 = motor electrical input + 2.3 amps; - Level 3 = motor electrical input + 2.6 amps;
- Level 4 = motor electrical input + 3 amps;
Press the arrow button
parameter.
The programmer checks the electrical input to the motor, detecting any eventual increase in effort above the
normal operating limits and intervenes as an additional safety device.
If the sensor intervenes during the opening direction the gate inverts the travel direction immediately and
proceeds to the fully open position. If the sensor intervenes during the closing direction the gate automatically
inverts the travel direction of a few centimetres and then stops to free the obstacle.
If automatic closing is enabled it will wait for the pause time to elapse and then close.
- Level 3 = motor electrical input + 4 amps;
- Level 5 = motor electrical input + 6 amps.
to confirm. The programmer will save the choice and move to the next
- Level 5 = motor electrical input + 3.5 amps.
to confirm. The programmer will save the choice and move to the next
56
4b) Current sensor
MOTOR SELECTION
SLX3024
3000kg
CURRENT SENSOR
LEVEL 1
LIMITED
OPENING
2 METERS
4b) Current sensor
MOTOR SELECTION
BL3924MCB
CURRENT SENSOR
LEVEL 1
LIMITED
OPENING
SELECTION 1