Pressure differences
The pressures of the cold and hot water
connections must be balanced.
Adjustment
Correction is necessary if the temperature
measured at the take off point differs from the
temperature set on the scale. To adjust
temperature proceed as follows: Turn the setting
knob until water at a temperature of 38 C comes
out of the outlet. Loosen screw of setting knob.
Remove setting knob and turn to the 38 C
position. Attach setting knob again and tighten
the screw (please see page 8).
Temperature limitation
The temperature is limited by the safety check to
38 C (100 F). If a higher temperature is
required, it is possible to override the safety stop
by depressing the safety button.
Safety Function
The desired maximum temperature for example
max. 42 C can be pre-set thanks to the safety
function. see page 8
Technical Data
Operating pressure:
Recommended operating pressure: 0,1 – 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
hand shower (1)
body shower 8 pieces (2)
hand shower + body shower (1+2)
Flow heater
Applicable for flow heaters at min. 24 kW and
0,15 MPa flow pressure before the Shower panel
and a minimum through flow of 7 l/minute. Only
one consumer possible, not two simultaneously.
16
English
max. 1 MPa
1,6 MPa
max. 80° C
65° C
16,8 l/min
18,0 l/min
22,3 l/min

Maintenance

There is no special maintenance for thermostats.
However, once a year the function of the non-
return-valve (21) has to be checked. At this time,
please also check the filter (16.1) situated on the
MTC-ther-moelement (16). After assembling the
MTC-thermo-element, it is necessary to check
the water temperature at the take off point as
described under the headline „adjustment".
Before the adjustment, please check, if the warm
water supply is activated and the maximum
temperature of the warm water is available at the
take off point.
To guarantee the smooth running of the
thermostat, it is necessary from time to time to
turn the thermostat from total hot to total cold.
Spare parts see page 15
1
upper cover
2
hand shower
3
support, assy
4
hose
5
flange
6
body shower
7
shut off unit with selector
8
rosette carrier
9
flange
10
sleeve
11
adapter for handle
12
handle
13
handle for thermostat
14
adapter for handle
15
sleeve
16
thermostat cartridge
17
sealing set
18
mounting set
19
screw M5 x 20
20
noise reduction
21
non return valve
22
extension 25 mm
97324000
28518000
97117000
97325000
97326000
28406000
97327000
97328000
97329000
96446000
96451000
96421000
38391000
96435000
96439000
94282000
95037000
96179000
96525000
94073000
97350000
13595000

Werbung

loading

Diese Anleitung auch für:

Raindance duschpaneel 27100000