Technische Kennwerte
Messbereich
Funktion
Messgröße
(Anzeigebereich)
0 ... 99,9 V
U
L–PE
100 ... 300 V
U
/ U
U
N–PE
L–N
(0 ... 600 V)
L–PE
U
N–PE
15,0 ... 99,9 Hz
f
(15,0 ... 650 Hz)
0 ... 99,9 V
U
U
100 ... 500 V
3~
3~
(0 ... 600 V)
U
0 ... 99,9 V
I∆N
10 Ω ... 9,99 kΩ
R
/ I
= 10 mA
∆N
E
3 Ω ... 999 Ω
R
/ I
= 30 mA
∆N
E
1 kΩ ... 6,40 kΩ
1Ω ... 999 Ω
R
/ I
= 100 mA
∆N
E
0,3 Ω ... 99,9 Ω
R
/ I
= 300 mA
∆N
100 Ω ... 640 Ω
E
0,2 Ω ... 99,9 Ω
R
/ I
= 500 mA
∆N
100 Ω ... 380 Ω
E
I
∆
I
/ I
= 10 mA
3,0 ... 13,0 mA
∆
∆N
I
/ I
= 30 mA
9,0 ... 39,0 mA
∆
∆N
I
/ I
= 100 mA
30 ... 130 mA
∆
∆N
I
/ I
= 300 mA
90 ... 390 mA
∆
∆N
I
/ I
= 500 mA
150 ... 650 mA
∆
∆N
U
/ U
= 25 V
0 ... 25,0 V
I∆
L
U
/ U
= 50 V
0 ... 50,0 V
I∆
L
t
(I
/5 · I
/
0 ... 99,9 ms
∆N
∆N
A
150 mA)
100 ... 999 ms
0 ... 0,49 Ω
0,5 ... 9,99 Ω
Z
SCHL
10,0 ... 30,0 Ω
Z
SCHL
0 ... 99,9 Ω
Z
15 mA
100 ... 250 Ω
SCHL
0 ... 0,49 Ω
0,5 ... 9,99 Ω
10,0 ... 99,9 Ω
R
R
E
E
100 ... 999 Ω
1,00 k ... 9,99 kΩ
Referenzbedingungen
230 V ± 0,1%
Netzspannung
50 Hz ±0,2 Hz
Netzfrequenz
Kurvenform der
Messgröße
Sinus (Abweichung zwischen Effektiv-
und Gleichrichtwert < 1%)
cos ϕ = 1
Netzimpedanzwinkel
5,5 V ± 1%
Batteriespannung
Umgebungstemperatur + 23 °C ± 2 K
40 ... 60%
Relative Luftfeuchte
Fingerkontakt
bei Prüfung Potentialdifferenz auf Erd-
potential
Nenngebrauchsbereiche
Spannung U
230 V
N
Frequenz f
16
N
50 Hz
60 Hz
Gesamtfrequenzbereich 15 ... 70 Hz
Kurvenform
Sinus
0 °C ... + 40 °C
Temperaturbereich
4,6 ... 6,5 V
Batteriespannung
entsprechend cosϕ = 1 ... 0,95
Netzimpedanzwinkel
GOSSEN METRAWATT GMBH
Auf-
Eingangsimpe-
lösung
danz/Prüfstrom
0,1 V
1 V
500 kΩ
0,1 Hz
500 kΩ
0,1 V
1 V
500 kΩ
0,1 V
0,3 · I
∆N
10 Ω
3 Ω
10 Ω
1Ω
0,3 ... 1,3 · I
0,3 Ω
1 Ω
0,2 Ω
1 Ω
3,0 ... 13,0 mA
0,1 mA
9,0 ... 39,0 mA
30 ... 130 mA
0,1 mA
1 mA
90 ... 390 mA
1 mA
150 ... 650 mA
0,1 V
wie I
∆
0,1 ms
1,05 · I
/ 5 · I
∆N
1 ms
10 mΩ
10 mΩ
740 mA
100 mΩ
100 mΩ
15 mA
1 Ω
10 mΩ
740 mA
10 mΩ
740 mA
10 mΩ
400 mA
100 mΩ
40 mA
1 Ω
4 mA
(108 ... 253 V)
2
Hz (15,4 ... 18 Hz)
/
3
(49,5 ... 50,5 Hz)
(59,4 ... 60,6 Hz)
Prüfgerät DIN VDE 0100
Nennwerte
—
—
—
+(12,5% v. M. + 2 D)
∆N
U
= 120 V
N
U
= 230 V
N
f
= 50 Hz
N
U
= 25/50 V
L
I
= 10/30/100/
∆N
300/500 mA
+(12,5% v. M. + 2 D)
∆N
U
= 120 V
N
U
= 230 V
N
f
= 50 Hz
N
Stromversorgung
Batterien
Batterietest
Batteriesparschaltung
Sicherheitsabschaltung
Ladebuchse
PROFiTEST
Nenngebrauchs-
Eigenabweichung
bereich
±(2% v. M. + 2 D)
108 ... 253 V
±(0,1% v. M. + 1 D)
15 ... 70 Hz
±(2% v. M. + 2 D)
108 ... 440 V
5 ... 70 V
+(2,5% v. M. – 2 D)
—
Rechenwert
3,0 ... 13,0 mA
9,0 ... 39,0 mA
±(5% v. M. + 2 D)
30 ... 130 mA
90 ... 390 mA
150 ... 650 mA
0 ... 25,0 V
+(2,5% v. M. – 2 D)
0 ... 50,0 V
±3 ms
0 ... 1000 ms
±5 D
0,25 ... 0,49 Ω
±(6% v. M. + 3 D)
0,50 ... 9,99 Ω
±(6% v. M. + 3 D)
10,0 ... 30,0 Ω
±(6% v. M. + 5 D)
0,50 ... 99,9 Ω
±(6% v. M. + 3 D)
100 ... 250 Ω
±5 D
0,25 Ω ... 0,49 Ω
±(6% v. M. + 3 D)
0,50 Ω ... 9,99 Ω
±(4% v. M. + 3 D)
10,0 Ω ... 99,9 Ω
±(4% v. M. + 3 D)
100 Ω ...999 Ω
±(4% v. M. + 3 D)
1 kΩ ...9,990 kΩ
4 Stück 1,5 V-Babyzellen (4 x C-Size)
(Alkali-Mangan gemäß IEC LR14)
oder 4 NiCd/NiMH-Akkus
symbolische Anzeige
Die Anzeigebeleuchtung ist abschalt-
bar. Das Prüfgerät schaltet sich
10 ... 60 Sekunden nach der letzten
Tastenbetätigung automatisch ab.
Die Einschaltdauer kann vom Anwender
selbst gewählt werden.
Das Gerät schaltet bei zu niedriger Ver-
sorgungsspannung ab bzw. kann nicht
eingeschaltet werden.
Eingelegte Akkus können durch
Anschluss des Ladenetzteils NA0100S
(Z501D) an die Ladebuchse direkt auf-
geladen werden
C
Betriebsmess-
abweichung
±(4% v.M. + 3 D)
±(0,2% v.M. + 1 D)
±(4% v.M. + 3 D)
+15% v.M. + 2 D
+0%v.M. – 0 D
—
±(8% v.M. +2 D)
+15% v.M.+2 D
+0%v.M. – 0 D
±4 ms
±(10% v.M. + 5 D)
±(10% v.M. + 5 D)
±(10% v.M. + 5 D)
±(15% v.M. + 10 D)
±(10% v.M. + 10 D)
±(10% v.M. + 5 D)
±(10% v.M. + 5 D)
±(8% v.M. + 5 D)
±(8% v.M. + 5 D)
±(8% v.M. + 5 D)
3