Power tool
Single impact energy in accordance with
EPTA procedure 05/2009 (half power setting),
TE 60‑ATC‑AVR
Other information about the power tool
en
TE 60 / TE 60‑ATC‑AVR chuck
Protection class as per EN
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a
standardised test given in EN 60745 and may be used to compare one tool with another. It may be used for a
preliminary assessment of exposure. The declared vibration emission level represents the main applications of
the tool. However if the tool is used for different applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly increase the exposure level over the total working
period. An estimation of the level of exposure to vibration should also take into account the times when the
tool is switched off or when it is running but not actually doing the job. This may significantly reduce the
exposure level over the total working period. Identify additional safety measures to protect the operator from
the effects of vibration such as: maintain the tool and the accessories, keep the hands warm, organisation of
work patterns.
Noise and vibration information (measured in accordance with EN 60745‑2‑6):
Typical A‑weighted sound power level for the TE 60
with ATC and AVR
Typical A-weighted sound power level, TE 60
Typical A-weighted emission sound pressure level
for the TE 60 (with ATC and AVR)
Typical A-weighted emission sound pressure level,
TE 60
Uncertainty for the given sound level
Triaxial vibration values for the TE 60‑ATC-AVR (vibration vector sum)
Hammer drilling in concrete, a
Chiseling, a
h, Cheq
Uncertainty (K) for triaxial vibration value
Triaxial vibration value for the TE 60 (vibration vector sum)
Hammer drilling in concrete, a
Chiseling, a
h, Cheq
Uncertainty (K) for triaxial vibration value
22
TE 60 / TE 60‑ATC‑AVR
3.6 J
TE‑Y
Protection class II (double insulated)
112 dB (A)
107 dB (A)
101 dB (A)
96 dB (A)
3 dB (A)
7.5 m/s²
h, HD
7 m/s²
1.5 m/s²
18.5 m/s²
h, HD
15.5 m/s²
1.5 m/s²