1) Switch the machine off by means of the ON/OFF switch and remove the plug from the power socket.
2) Remove the rear panel by unscrewing the 10 posterior fixing screws using a No. 3 T male hex wrench.
Attention! The 2 screws
3) Remove the fusebox capsule by turning it anticlockwise through half a turn and replace the blown fuse with a new
fuse having the features shown in the Table.
4) Refit the rear panel by fixing the 10 screws using a No. 3 T male hex wrench , as well as the two screws
Rev. 08 - 04/2017 - Cod. 1500160 - Instruction manual VGP25N / VGP60N
A
on the upper edge of the panel can only be accessed with the sealing head open.
A
ROUTINE MAINTENANCE
A
.
53