Herunterladen Inhalt Inhalt Diese Seite drucken

RIB IDRO Serie Bedienungsanleitung Seite 18

Vorschau ausblenden Andere Handbücher für IDRO Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
G G
B B
O
PERATOR INSTALLATION
If there is an iron pillar you can weld the anchorage directly.
If there is a cement pillar, you can cement the anchorage welding an
anchor Fig. 2 with the base.
Afterwards you must weld the actuator to the gate.
Naturally you have to respect the measures predetermined (Fig.3).
N.B.: Ensure that when the door is fully open and fully closed the
rod is not at the end of its stroke, but is at least 15mm from
the end of its stroke on each side.
Fix the IDRO and try several times to open and to close the gate,
controlling that the cover does not touch the moving gate, otherwise you
have to readjust the ancorage on the gate.
In the case you have a wall parallel with the open gate, you must
provide a niche in which to place the operator.
α
B
L
L
EAF
ENGHT
1 ÷ 1,6 m
100
1,8 ÷ 2,5 m
110
95°
1 ÷ 1,8 m
100
1,8 ÷ 2,5 m
110
α
L
L
B
EAF
ENGHT
1,2 ÷ 1,8 m
90°
200
1,2 ÷ 1,8 m
90°
220
1,2 ÷ 1,8 m
90°
260
1,8 ÷ 2,5 m
200
90°
1,8 ÷ 2,5 m
220
90°
2,5 ÷ 3 m
120
115°
3 ÷ 3,5 m
130
100°
3,5 ÷ 4 m
90°
140
4 ÷ 4,5 m
105°
130
4,5 ÷ 5 m
95°
140
5 ÷ 6 m
140
90°
6 ÷ 7 m
150
90°
L=> Motor travel to open 90°.
If the pillar is too large, and it is not possible to adjust the operator respecting the measure (B),
you must make a niche in the pillar or you have to move the gate to the edge of the pillar.
A = 970
C
D
L
M
S
OTOR
UGGESTED
IDRO 27/1B
90
50
190
IDRO 27/R
100
60
210
190
IDRO 27 SUPER/1B
90
50
IDRO 27 SUPER/R
100
60
210
A=1210
C
D
L
M
S
OTOR
UGGESTED
140
390
IDRO 39/1B
190
390
IDRO 39/1B
160
160
IDRO 39/1B
120
200
390
IDRO 39/R
190
140
390
IDRO 39/R
160
390
160
IDRO 39/R
70
230
110
80
250
IDRO 39/R
120
90
270
IDRO 39/R
130
250
IDRO 39/R
120
70
IDRO 39/R
120
80
260
IDRO 39/R
130
90
270
IDRO 39/R
100
270
140
Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
with manned operation
A
with visible impulses
C
(e.g. sensor)
with not visible impulses
C
(e.g. remote controldevice)
automatic
C and D
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated), like
code ACG2020.
B: Key selector with manned operation, like code ACG1010.
C: Safety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
D: Photocells, like code ACG8026.
T
IME
11"
11"
16"
18"
T
IME
47"
47"
47"
47"
47"
27"
30"
32"
30"
31"
32"
32"
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
C
C and D
C and D
C and D
C and D
C and D
Measurements in mm
2
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Idro 27Idro 39

Inhaltsverzeichnis