Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Device; Cleaning And Maintenance - Velleman VDL1003MCD Bedienungsanleitung

Mini cross dancer 3 x 100w
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks,
crash, etc. Using the device in an unauthorised way will void the warranty.
4. Lamps
• You need 3 x R7S 100W/230V lamps (order code: LHALR7S100).
• Never touch the lamp with your bare fingers.
Procedure:
1. Unscrew the 3 screws on the top of the housing (holding the half ball with the colour lenses).
2. Remove the half ball.
3. For re-lamping remove the old ones and replace 3 new lamps.
4. Replace the half ball.
5. Fasten the 3 screws.

5. Mounting the device

• The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour
without any harming deformation.
• The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety cable
(VDLSC7 or VDLSC8).
• Never stand directly below the device when mounting, removing or servicing the fixture
• The operator has to make sure the safety relating and machine technical installations are approved by an expert
before taking the device into operation for the first time. These installations have to be approved by a skilled
person once a year.
• The effect should be installed outside areas where persons may reach it, walk by or be seated.
• Overhead mounting requires extensive experience, including amongst others calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and the device. If you
lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
6. Use
• Connect the fixture to the mains with the power plug. In general, lighting effects
should not be connected to dimming packs. Flick the power switch to the ON
position. The fixture will start producing colourful light beams at a steady pace. You
can change the sensitivity of the sound trough a knob (2) on the backside.
• There is a microphone (1) on the backside to run the fixture on sound control.
• When re-lamping or fixing problems, always re-fuse with the correct fuse (3A, order
code: FF3N).

7. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections, ...
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
VDL1003MCD
2
VELLEMAN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis