Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (open water
heaters) is not possible.

Safety notes

• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.

Technical data

• Flow pressure:
- min.
- recommended
• Operating pressure:
• Test pressure:
If static pressures exceed 0.5 MPa (5 bar), a pressure-
reducing valve must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa (3 bar) flow pressure:
• Hot water supply temperature:
Recommended (energy economy):
• Voltage supply:
• Automatische Sicherheitsabschaltung:
(5 - 420 s einstellbar)
• Automatic safety shut-off:
(5 - 420 s adjustable)
• Run-on time (0 - 10 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (factory setting): approx. 13cm
• Type of fitting protection:
• Water connection
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
GB
0.05 MPa (0.5 bar)
0.1 - 0.5 MPa (1 - 5 bar)
max. 1 MPa (10 bar)
1.6 MPa (16 bar)
approx. 6 l/min
max. 70 °C
60 °C
6V lithium battery type CR-P2
60 s
60 s
1 s
IP 59K
cold - right
hot - left
A
2
2500 V
100 °C
21
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Approval and conformity
This product conforms to the requirements of the
relevant EU directives.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Flush pipes thoroughly before and after installation
(observe EN 806).

Operation

The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Setting temperature limiter, see page 3, fig. [9] and [10].
activatable
readable
activatable
deactivated
3.5 min