Herunterladen Diese Seite drucken

Balluff BML SGA-AEZ1-LZZZ-TU11-S284 Kurzanleitung Seite 7

Absolutes magnetkodiertes wegmesssystem

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BML SGA-AEZ1-LZZZ-TU11-S284
Absolute Magnetically Coded Position Measuring System
Construction and function (continued)
Linear application
–Roll
+Roll
5
5
Linear application
Z
(gap between sensor head/magnetic
tape)
Z
(gap between sensor head/magnetic
tape with cover strip)
Y (side offset)
Pitch
Yaw
Roll
Max. non-linearity of entire system
(sensor head + magnetic tape)
Non-linearity of sensor head
Hysteresis
Repeat accuracy
1) The different mounting tolerances must be met depending on the required measuring accuracy.
Curved application
Curved application
Z (gap between sensor head/
magnetic tape)
Z (gap between sensor head/
magnetic tape with cover strip)
Y (side offset)
X (tangential offset)
Pitch
Yaw
Roll
www.balluff.com
Active measuring surface
Free area of magnetizable
material
Travel direction:
forward, A (sin) before B
(cos)
Working range 1
≤ 0.3 mm
≤ 0.15 mm
±0.5 mm
±12 µm
±2 µm
≤ 1 µm
≤ 1 µm
Z
X
2000 mm
≤ 0.7 mm
0.55 mm
Z
1)
Working range 2
1)
≤ 0.8 mm
≤ 0.65 mm
±1.0 mm
±0.5°
±1°
±0.5°
±30 µm
±20 µm
≤ 2 µm
≤ 2 µm
–Pitch
+Pitch
Z
Diameter
1000 mm
≤ 0.6 mm
0.45 mm
±0.5 mm
34.6 mm ±0.5 mm
±0.5°
±1°
±0.5°
34.6
Y
+Yaw
–Yaw
–Pitch
+Pitch
Function range
1)
≤ 1.3 mm
≤ 1.15 mm
±1.5 mm
±100 µm
±40 µm
≤ 25 µm
≤ 2 µm
Tangential point
400 mm
≤ 0.2 mm
english
2

Werbung

loading