Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning; Earth Control Measurement After Installation/Service - Nederman 889 Ex-Serie Bedienungsanleitung

Hose reel
Vorschau ausblenden Andere Handbücher für 889 Ex-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
7

Commissioning

Before every use, the hose reel must always be checked for visible damage to the hose reel
and accessories, in particular the hose equipment and hose connections.
Dust deposits and caked layers must be removed, especially from the rotating parts such as
the inside and outside of the drum, taking care not to stir up the dust. Test the operation of
the rotating parts for example the swivel and the hose outlet.
Especially at temperatures below 0 °C, if water is used as the medium, ensure that remains
of the medium do not freeze and cause the hose reel to stop functioning. The remains of the
medium must be emptied from the hose.
WARNING!
Risk of personal injury.
Defective parts must be replaced or necessary repair work carried out in suitable specialist
workshops before every use. Only original replacement parts must be used.
WARNING!
Risk of personal injury.
Check the operation of the shutoff device on the supply pipe system.
Check that the ATEX zone marking and the medium, with pressure and temperature, are
permitted for the intended use (see type label).
Mounting instruction:
See Instruction Manual.
Connecting to the pipework system:
See Instruction Manual.
Avoid contact with chemical products.
Where accessories are used, they must be installed securely and without leaks.
The additional safety requirements must be observed when accessories are used.
WARNING!
Risk of personal injury.
The carried medium must never be released unless the end of the supply hose, with any
accessories, is held firmly in the hands.
CAUTION!
Risk of equipment damage.
Hose whip if the end of the supply hose is loose.
WARNING!
Risk of personal injury.
Only release the extended supply hose when the ratchet mechanism is securely engaged at the
reel.
When retracting, hold the supply hose firmly in the hands until the hose stop reaches the hose
outlet.
8

Earth control measurement after installation/service

Check the earthing between the coupling of the supply hose and the earth point of the hose
reel. The ohmmeter must indicate less than 50x10
Check the earthing between the coupling of the intake hose and the earth point of the hose
reel. The ohmmeter must indicate less than 50x10
ohm (R < 50M Ω). See figure 1.
6
ohm (R < 50M Ω). See figure 2.
6
Series 889 Ex