Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Maintenance; Operation - Grohe Chiara 19 157 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Specifications
Flow rate at 3 bar flow pressure:
- Spout
- Shower
Temperature
- Scalding protection possible by fitting a temperature limiter
(see replacement parts fold-out page II, order no. 46 308).

Installation

Installing hose guide, see fold-out page I.
1. Remove protective sleeves (A1) and top plate (A), see
Fig. [1].
2. Fit hose guide (B) to top plate (A).
3. Shut off cartridge and open cold- and hot water connection.
4. Mount shower hose (C) with shower connection hose (C1)
from rough installation, see Fig. [2].
5. Slide spring (K) on shower hose (C) and push through hose
guide (B).
6. Screw coupling (D) onto shower hose (C).
Locate top plate (A).
Install spout and handshower
1. Screw handshower (E) to coupling piece (D), see Fig. [3].
2. Fit spout (G) with seal (G1) to the shank (H), tighten grub
screw (J) with 4mm socket spanner and screw on top
plate (J1).
Install escutcheon and lever
1. Screw on cap (L), see Fig. [4].
2. Push on escutcheon mounting base (M) and secure with
screws (M1).
3. Grease inner seal (N1) and push on.
4. Clip in escutcheon (N).
5. Fit lever (O), secure by tightening the loosely fitted set
screw (O1) with 3mm socket spanner and insert plug (O2).
Grout the joint around the top plate with permanently
elastic material.
In this way, the inspection chamber will be accessible at any
time!

Operation

a) Lever, see fold-out page III, Fig. [5]
b) Diverter
Pulling the lever will release water supply.
Water will emerge from the bath spout first.
Pull diverter knob
= to divert flow from bath spout to
shower outlet
Press diverter knob
= to divert flow from shower outlet
to bath spout
Flow is diverted automatically from shower outlet to bath spout
when the mixer is turned off.

Maintenance

Inspect and clean all parts, replace as necessary and grease
with special grease.
approx. 22,5 l/min
approx. 13 l/min
Shut off the hot and cold water supply!
I. Cartridge, see Fig. [6].
1. Lever out plug (O2).
2. Loosen set screw (O1) with 3mm socket spanner and pull
off lever (O).
3. Pull off escutcheon (N) and O-ring (N1).
4. Screw out screws (M1) and detach ecsutcheon mounting
base (M).
5. Unscrew cap (L).
6. Remove screws (R) and detach complete cartridge (S).
7. Change either the complete cartridge (S).
Assemble in reverse order.
Observe the correct installation position.
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (R) and tighten evenly
and alternately.
II. Diverter, see Fig. [7].
1. Pull off cover cap (T).
2. Screw out screw (T1) and detach diverter knob (T2).
3. Unscrew diverter (U) by using a 17mm socket wrench.
III. Shower hose, see Figs. [8] and [9].
1. Pull out shower hose (C) and remove handshower (E)
from coupling piece (D), see Fig. [8].
2. Unscrew and remove guide (D1) with integratet shower
seal, see Fig. [9].
3. Pull out the shower hose (C) until shower connection
hose (C1) projects.
4. Secure the shower connection hose (C1) against slipping
down again.
5. Disconnect shower hose (C) and pull off spring (K).
IV. Unscrew and clean aerator (13 907), see fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this mixer, please refer to the
accompanying Care Instructions.
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis