Operating and assembly instructions SD
Side channel blowers with an in-built frequency convert-
er (FUK):
Devices with an in-built frequency converter meet the re-
quirements of the EC "Electromagnetic Compatibility" Direc-
EN
tive 2014/30/EU under consideration of EN 61800-3 Catego-
ry C2 (industrial environment), taking into account the EMC
instructions from the frequency converter and the information
in the Elektror operating and assembly instructions .
Warning!
This product may cause high-frequency inter-
ference in a residential environment that may
require screening measures.
A CE conformity assessment with the relevant standards and
guidelines must be carried out in all cases before the start-
up.
4 INSTRUCTIONS FOR OPERATION
AND USE
4.1 Basic information
Please observe the notes on designated use in section 1.1,
as well as the safety guidelines in sections 1.2 to 1.12.
If electrical current drops below the rated current of the drive
motor during operation, check to see if the mains voltage and
frequency match the appliance ratings.
After protective shutdowns, e.g. tripping of the motor circuit-
breaker, activation of the PTC evaluation unit by motors with
a PTC resistor sensor, or after a protective shutdown of the
frequency converter during FU applications, the appliance
must not be restarted until the problem has been identifi ed
and eliminated.
If the side channel blower cannot be operated over the whole
range of the characteristic curve, the motor may overload
if the system resistance is too high (excessive current con-
sumption). If the possibility of overload due to system resist-
ance cannot be excluded, a pressure limiting valve must be
provided on the intake or pressure side.
The side channel blower must not be subjected to vibration
or impact loads.

4.2 Frequency converter operation

14
A frequency converter is used, allowing a wide range of
speed adjustments. There is only a small, load-related diff er-
ence in rpm between idle state and the max. load of the side
channel blowers.
To ensure trouble-free operation of the side channel
blowers, it is important that the converter meet the fol-
lowing requirements:
• Converter output equal to or greater than motor power
output *)
• Converter current equal to or greater than motor current *)
• Converter output voltage equal to rated motor voltage
• Supply voltage max. 480V, including 5% voltage tolerance
• The pulse frequency of the converter should be 8 kHz,
since a lower pulse frequency can cause very noisy motor
operation.
The values for the maximum/minimum frequency can be
found at 1.12.
• The converter should have a connection for a tempera-
ture sensor (PTC resistor sensor) or a temperature switch
(normally-closed contact)
*) Refer to the rating plate for data
The motor can be operated in a delta or star-point confi gu-
ration, depending on the input voltage of the converter.
The following U/f assignments must be confi gured at the
converter.
U
B
0
f
and U
= refer to rating plate
B
B
If this is ignored, the motor current will increase dispropor-
tionately and the drive motor will fail to achieve its rated
speed.
Warning!
To avoid personal damage, destruction of the
side channel blower or motor overload, a higher
frequency (speed) than the frequency (f
fi ed on the rating plate must never be set on the
converter otherwise the motor may be overloaded
or the blower destroyed due to the increased
speed. The temperature sensors are connected to
the corresponding converter inputs to protective
the drive motor. Single-phase alternating current
motors are not suitable for converter operation.
It is absolutely essential that you observe the
installation and safety instructions described in
the respective operating or application manuals
provided by the frequency converter supplier to
guarantee a safe and trouble-free operation.
It is also important to note that special ambient
conditions may lead to a high level of contamina-
tion of the cooling fi ns with the FUK devices. The
frequency converter switches off if the cool-
ing output on the cooling fi ns is not adequate.
Regular cleaning is required for devices in these
environments.
Note!
The following times apply for the respective
device motor output class (see rating plate) with
run-up/expiry as well as speed changes in order
to avoid high component loads and faults in the
converter operation:
Device motor output
Motor output < 0.25 kW
0.25 kW < Motor output
<=3.0 kW
3.1 kW < Motor output
<= 7.5 kW
7.6 kW < Motor output
<= 11.0 kW
11.1 kW < Motor output
<= 30.0 kW
A uniform run-up and expiry must be guaranteed within the
run-up and expiry times.
No speed changes must occur during operation that exceed
the speed change during run-up and expiry.
www.elektror.com
Prohibited
range
f
B
) speci-
B
Run-up time
Expiry time
[s]
[s]
5
10
10
20
20
40
30
60
30
100