A clean soft cloth or wet sponge can be
used for the cleaning.

7. MAINTENANCE

WARNING!
Before any work on the
appliance, disconnect all
poles of the appliance from
the power supply.
The water heater requires no special
maintenance. The anode rod helps
protect the tank against corrosion.
Depending on the water condition, the
magnesium anode rod may need to be
changed every 2 years. Galvanic and
electrolytic corrosion can damage the
tank if the anode rod worn out. Rusty
water is usually an indication of a worn
out anode rod. If rusty water is present,
you must call the authorized
professionals immediately in order to
examine anode rod and replace if
necessary.
There are some points to check when
you make the required maintenance for
this appliance.
7.1 Checking the safety valve
Check the function of the safety valve
regularly.
7.2 Draining the appliance
WARNING!
Hot water may escape
during the draining process.
Drain the appliance via its connectors.

7.3 Opening the appliance

1. Pull off the temperature selector and
the limiting ring.
Dis-solvent products are not allowed for
the cleaning.
2. Remove the 4 screws from the
casing.
3. Open the appliance cover by
pivoting the cover upwards and then
removing it.
4. Remove the upper insulation semi-
shell if required.