Herunterladen Diese Seite drucken

Solvis BE-SC-2 Montageanleitung Seite 7

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Scope of delivery and installation notes
Scope of delivery and installation notes
The sensor cable may be extended with
a suitable cable (e.g. 2 x 0.5 mm²).
Room controller BE-SC-2
Scope of delivery
• Room controller
• Installation material
• Instructions (enclosed)
Function
Measuring the room temperature and
remote control of the controller
Before installation
The room controller must be installed in
the coldest room you wish to heat.
It must not be installed in close proximi-
ty to a heat source or near a window .
L 80-M – Subject to technical changes 08.16
Depending on the application, there are
two different versions of the room con-
toller:
Room controller BE-SC 2-O-SEN
• Room controller without sensor with in-
tegrated connection terminal
• Installation material
• Instructions (enclosed)
Please order separately:
• Contact sensor SEN-A-105-PT (incl.
heat-conducting paste and clamp fitting)
Use as a pool sensor to measure swim-
ming pool temperature and for remote
control of controller
The BE-SC-2-O-SEN must be mounted in
a space that is protected from the
weather. The contact sensor is connect-
ed to the connection ter minal located in-
side the BE-SC-2-O-SEN (any polarity) and
installed in the return of the swimming
pool circuit.
EN
7

Quicklinks ausblenden:

Werbung

loading