Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Monuments IRON III Montage- Und Gebrauchsanweisung

Sauna-heizgerät mit integrierter steuerung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Wiring diagram and connections
6,0 / 7,5 / 9,0 kW
N
L1 L2 L3
Light
Leuchte
bauseitige Installation

Technical specifications

Heater power as
Heater dimensions
per DIN
H/W/D in cm
6,0 kW
64 (86*) / 44 / 33
7,5 kW
(*at 22 cm gap FFL)
9,0 kW
All information on cable cross-sections are minimum cross-sections in mm² copper line.
Leakage current: max. 0.75 mA per kW of heating power.
To be connected by a qualified electrician:
Drill an approx. 10 mm hole in the cabin wall near the entry area of the stove's connecting cable. Feed the connecting cable through
the borehole to the outside and connect to the power supply in a distribution box suitable for wet rooms.
Please observe the wiring diagram and the regulations of the local power supplier (TAB 2000) and the VDE.
Caution!
An adequate fuse and a mains circuit breaker must be installed in the stove's power cable on site.
24
5 x 2,5²
Zeitschaltuhr
timer
A
A
B
5 x 1,5²
max. 10 m
Attention!
Always connect the neutral wire N.
Achtung! Immer Nulleiter N mit anklemmen.
Minimum
Weight without
Suitable for
dimensions of air
rocks and
sauna cabin
intake and exhaust
packaging
vents
6 - 8 m³
35 x 4 cm
8 - 12 m³
35 x 5 cm
13,5 kg
9 - 14 m³
35 x 6 cm
A1
A1
M
B1
L1
L2 L3 N PE
Netz
main
400V AC 3N
Stone filling
electrical
connections
(not included in the
delivery)
400 V 3N AC
15 kg
50 Hz
EN
Sicherheits-
temperaturbegrenzer
Thermostat
overheat safty
Thermostat
shutdown device
A1
B1
A2
B2
A3
B3
6,0 kW = 3x 2000 W
7,5 kW = 3x 2500 W
9,0 kW = 3x 3000 W
use protection of
temperature
controller, A
control range
3 x 16
40 - 100°C
reset
Connection
mains - heater
5 x 1,5
max. 10 m

Werbung

Inhaltsverzeichnis
loading