Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold the
shower head. Do not load it down with other objects!
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system
without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this shower
system.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
The hot and cold supplies must be of equal pressures.
Assembly (see page 5)
Important! The fitting must be installed, flushed and
tested after the valid norms.
Where the contractor mounts the product, he should ensure
that the entire area of the wall to which the mounting plate
is to be fitted, is flat (no projecting joints or tiles sticking out),
that the structure of the wall is suitable for the installation
of the product and has no weak points.
The enclosed screws and dowels are only suitable for
concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken
into account.
The filter (A) must be insert to protect the hand shower
against incoming dirt by pipework. Incoming dirt leads
to defects or/and can damage parts of the hand shower;
such caused faults voids all liability and guarantee claims.
(see page 8)
English

Adjustment

Correction is necessary if the temperature measured at the
take off point differs from the temperature set on the scale.
To adjust temperature proceed as follows: Turn the setting
knob until water at a temperature of 38 C comes out of
the outlet. Loosen screw of setting knob. Remove setting
knob and turn to the 38 C position. Attach setting knob
again and tighten the screw (please see page 9).
Maintenance
There is no special maintenance for thermostats.
However, once a year the function of the non-return-
valve (94074000 see page 8) has to be checked. At
this time, please also check the filter (6.1) situated on the
MTC-thermoelement (94282000). After assembling the
MTC-thermoelement, it is necessary to check the water
temperature at the take off point as described under the
headline „adjustment". Before the adjustment, please
check, if the warm water supply is activated and the
maximum temperature of the warm water is available at
the take off point.
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
anti-pollution function
Hansgrohe showers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0,15 MPa before the shower
fitting.
Spare parts (see page 4)
Operation (see page 12)
Cleaning (see page 13)
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80° C
65° C
150 mm
cold right
hot left
17