Installation

Integrata is supplied without pre-drilled fixing holes, which allows you much greater
freedom when installing the unit to the ceiling.
The control box can be mounted in the external flange or in the vertical side.
If you drill through the extractor unit then the hole should be placed as far out to the
corner as possible.
The following must be observed prior to installation:
The air ventilation outlet must be connected through either the roof or a wall.
Construct a base that can support the ceiling unit.
Integrata is supplied with cables, built-in indicator panel with reset button and remote
control. The ceiling unit must be mounted in the ceiling.
The remote control receiver must be placed beside the ceiling unit in the room.
Feeding off the ceiling unit are:
1 x flat cable for remote control receiver.
1 x cable for the power supply (labelled: 230V)
1 x cable for external motor (labelled: motor). The cable must feed directly to the motor.
It is important not to use a common earth
as this will damage the electrical system of the unit.
When connecting directly to the mains (without a plug) it is necessary to install a multi-pole
circuit breaker between the mains and the unit electrical system. The circuit breaker must
be of a size and type in accordance with existing legislation on power supply.
This product MUST be earthed in order for the warrantee to be valid.