AXIS P1365-E Network Camera
RS485/422 Connector
Two 2-pin terminal blocks for RS485/RS422 serial
interface. The serial port can be configured to support:
• Two-wire RS485 half duplex
• Four-wire RS485 full duplex
• Two-wire RS422 simplex
• Four-wire RS422 full duplex point to point
communication
Function
RS485B alt
RS485/422 RX(B)
RS485A alt
RS485/422 RX(A)
RS485/RS422 TX(B)
RS485/RS422 TX(A)
Important
The recommended maximum cable length is 30 m (98.4 ft).
SD Card Slot
The Axis product supports microSD cards with up to 64 GB of storage. For best recording
performance, use ultra-high speed microSD cards (microSDHC UHS-I or microSDXC UHS-I).
Cable Area
NO TICE
TICE
NO
NO
TICE
• Use cables that keep within the specified cable area.
• Select cables in compliance with your local regulations.
• Make sure all cable holes are properly sealed.
Diameter
5–15 mm (0.197–0.591 in)
Pin
Notes
1
RX pair for all modes (combined RX/TX for 2-wire RS485)
2
3
TX pair for RS422 and 4-wire RS485
4
RX/TX
1
2
3
AWG
Approximately 4–6/0
16
TX
4