1) DESTINATION OF USE
This product is destined exclusively for the opening and closure of swing doors for the passage of vehicles, characterised by dimensional
limits and weight as indicated in this manual in the "Limits of use" paragraph.
No other use is allowed.
Automatismi Benincà is not liable for uses that are not in compliance with those indicated in these instructions.
2) LIMITS OF USE
Table 1 indicates the maximum values (weight by leaf length) acceptable for the BOB automation
3) INTRODUCTION
• Before installing the system, read the instruction herein.
• It is mandatory not to use the BOB 50M / BOB 50ME item for applications different from those indicated in the instructions herein.
• Supply the end user with instructions for using this system.
• The end user should receive special instruction manual.
• All Benincà items are covered by an insurance policy for damages and injuries caused by manufacture faults. It is however required
that the machine bear the CE marking and original Benincà parts be used.
4) PRELIMINARY CHECKS
It is indispensable to carry out several checks before starting installation:
• Try and open the gate manually, the leaves must move without effort and without points of resistance for the entire run.
• When left in any intermediate position the leaf must not move.
• The hinges and components subject to wear must be in perfect working condition. If this is not the case, replace the faulty parts.
• The door structure must be strong and the leaves rigid.
• With the gate completely closed, check that the leaves are aligned perfectly along their entire length.
• The pillars supporting the leaves must be suitable for fixing the gear motors.
• BOB has adjustable mechanical stops both in opening and closing. However, a stop for closure on the ground is recommended.
The reliability and safety of the automation depend on the state of the gate structure.
Check that there is enough space for installation of the operator in safe and comfortable conditions.
5) HOW TO INSTALL THE AUTOMATIC SYSTEM
Calculate the height of the system from the ground (it is advisable to define a position as much centred as possible with respect to the
main door and in correspondence with a strong cross girder). Weld the plate P, following measures in Fig. 1.
With the door closed, weld bracket S to a cross beam of the main door or other element with equal strength, according to measures
shown in Fig. 1. Keep in mind that, when carrying out this operation, the actuator should not be totally in a stroke end position.
Remove the cover C by loosening the screw F. Then fix the actuator to the plate P by means of the screw T and the nut D (Fig. 2). Lock
the actuator to plate S by means of screw V and washer R.
The holes in the acturator (Fig. 1a-1b) help to keep to the optimum installation measures.
6) HOW TO ADJUST THE MECHANICAL STOPPERS
The actuator is provided with adjustable mechanical stoppers in the opening and closing phases. The system is adjusted by suitably positioning
the "Open" and "Close" mechanical locks, as shown hereunder (Fig.3):
1) Unlock the automatic system by using the special release lever, as shown in the instructions for the user (page 21-22).
2) Close the door/gate leaf.
3) Loosen screws V1 and move the "Close" lock until it reaches the pivot P, then tighten screws V1.
4) Open the door/gate leaf.
5) Loosen screws V2 and move the "Open" lock until it reaches the pivot P, then tighten screws V2.
6) Reset the automatic operating mode.
In the BOB 50M version, two limit micro-switches are provided fixed to the mechanical stoppers.
The micro-switches trigger slightly in advance with respect to the mechanical stop.
7) CONNECTIONS
1) The special plate P (Fig. 4) allows for using a link for sheath or cable gland PG11, or PG13,5. Once the type of cable gland is applied
to the plate, fix the latter to the adaptor cover by means of screws V.
2) Insert the cable, or cables, under the terminal board, as shown in Fig.5. This will leave enough space for the capacitor.
3) BOB 50M: carry out the wiring by referring to the wire diagram shown in Fig 6a (use both limit switches). In order to use either the
opening limit switch or the mechanical stoppers, change wiring as shown in Fig. 6b (opening limit switch only) or 6c (mechanical
stoppers only).
N.B: in wiring connections shown in Fig. 6a and 6b, the capacitor MUST NOT be connected to the control unit, while for wire
connection shown in Fig. 6c, the capacitor can be connected to the control unit.
4) BOB 50ME: carry out the wiring by referring to wire diagram shown in Fig 6d.
5) It is mandatory to provide for ground by using the special GND terminal.