Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Operation - HANSGROHE Talis S series Montageanleitung

Vorschau ausblenden Andere Handbücher für Talis S series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system
without proper supervision. Persons under the influence
of alcohol or drugs are prohibited from using this shower
system.
The hot and cold supplies must be of equal pressures.
Assembly (see page 32)
Important! The fitting must be installed, flushed and
tested after the valid norms.
Important! Do not use silicone containing acetic acid!

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Shower mixer: The flow is changed from bath to shower
function by pulling the knob at the upper side of the
spout. After shutting off the water flow, the mixer returns
automatically to the bath function.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work

English
Technical Data (see page 31)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections:
Rate of flow by 0,3 MPa:
anti-pollution function
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
To adjust the hot water limiter on single lever mixers, please
see page 35.
No adjustment is necessary when using a continuous flow
water heater.
Important! The non return valves must be checked
regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Spare parts (see page 34)
Cleaning (see page 36)
Cause
- Shower filter seal dirty
- Non return valve hasn't moved
back
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Filters are dirty
- Non return valve hasn't moved
back
150 mm ±12mm
cold right - hot left
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Clean aerator, replace as
necessary
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
max. 1 MPa
0,1 – 0,5MPa
1,6MPa
max. 80°C
65°C
18 l/min

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis