Seav LRX 2214 SWR Handbuch Seite 8

Elektronische steuereinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
and one for downward movement. Storing a BeFree series radio control (3 buttons)
produces three separate commands: the first button is used for upward movement, the
second for Stop and the third for downward movement.
Operation using a 1-button radio control:
The following type of operation is obtained using a radio control with a single button:
the first press controls the upward movement of the shutter until the motor timer stops.
The second press controls the downward movement of the shutter. If the button is
pressed before the motor stops running, the control unit will stop the shutter moving
and the button will need to be pressed again to reactivate the motor in the opposite
direction.
Operation using a 2-button radio control:
The following type of operation is obtained using a radio control with 2 buttons: the first
button ("Up", corresponding to upward movement) controls upward movement until
the motor stops running and the second button ("Down", corresponding to downward
movement) controls the downward movement of the shutter. If the upward movement
is interrupted with another "Up" command, the motor will continue to run in the upward
movement direction. If, however, the movement is interrupted with a "Down" com-
mand, the control unit will stop the motor.
The procedure remains the same for the downward movement phase.
Operation using a 3-button radio control (BeFree x1):
The following type of operation is obtained using the BeFree x1 radio control: the (Up)
button controls upward movement until the end of the motor running time, the (Stop)
button causes all movement to stop and the (Down) button controls downward move-
ment. If a Stop command is sent during upward or downward movement, the control
unit causes this movement to stop. If a command that is in the opposite direction to
the current movement is sent during upward or downward movement, the control unit
causes the shutter to change direction.
Operation using a 3-button radio control (BeFree x3 - X6):
When using the BeFree x3 - x6 radio control, you will obtain the same type of opera-
tion as previously described for the BeFree x1 version; furthermore, the buttons (-) and
(+) at the sides of the radio control may be used to select the (Up - Stop - Down) com-
mands for 6 different types of operation. Press and hold the two buttons on the sides
of the radio control (-) and (+) for a few moments to enable and disable Sun sensor
operation (this selection is confirmed by the brief up/down movement made by the
motor).
I
NVERSION OF THE ROTATION MOTOR
If you notice that when pressing the (Up) button on the radio-control the control unit
causes the shutter to move downwards instead of upwards, simply repeat the pro-
gramming procedure pressing the (Down) button instead of the (Up) button, or invert
the upward movement wire and the downward movement wire of the motor.
G
G
C
ROUP OR
ENERAL
ENTRALISATION
Centralisation via cable using buttons
The centralisation of two or more control units enables upward or downward move-
ment to take place simultaneously in the connected pieces of equipment.
Centralisation can be performed by connecting the three wires for inputs T3 (Up), T4
(Down) and the shared reference point "GND Signal" in parallel.
Centralisation via radio using a radio control
The centralisation of two or more control units enables upward or downward move-
ment to take place simultaneously in the pieces of equipment.
Centralisation is performed by entering two identical codes (buttons) from one radio
control onto all the control units, or a group of them which are situated at a maximum
distance of 20 metres from the point of command, in order to obtain general or partial
motion of more than one automation. To achieve satisfactory radio centralisation, the
installation site should be chosen carefully. The field of action is not only linked to the
technical features of the device, but also varies according to the radio-electrical condi-
tions of the site itself.
A
O
NEMOMETER
PERATION
The electronic control unit will cause the sun shade to move upwards every time the
wind exceeds the selected threshold.
S
S
O
UN
ENSOR
PERATION
The electronic control unit will send a command for the downward movement of the
sun blind after 10 minutes of bright conditions above the threshold selected for the Sun
sensor and indicated by the lit SUN LED. It will then send a command for upward
movement after 10 minutes at a brightness level which is lower than the selected
threshold.
R
S
O
AIN
ENSOR
PERATION
The electronic control unit will cause the sun shade to move upwards as soon as the
sensitive part of the Rain sensor detects water, indicated by the lit RAIN LED.
O
L
PERATING
OGIC
Step-by-step P/P + Aut Sensors
1) Step-by-step (Dip 1 and 2 OFF)
The electronic control unit has a cyclic "Step-by-Step" logic, the operation of which
depends on the type of control associated with it.
2) Step-by-step + Automatic sensors (Dip 1 ON and Dip 2 OFF)
The electronic control unit allows "Step-by-Step" operation as described above, with
the addition of automatic Wind and Rain sensor control. After one of the two sensors
has been activated, once the disturbance is over, the electronic control unit will send a
command for the downward movement of the sun blind after 10 minutes.
- 8 -
User Present
Venetian Blind

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis