make sure the rotation direction is correct. When installing the device, we recommend
the blind is placed in an intermediate position so that you can see all confirmation
movements during the test procedures. After checking the sensors are operating cor-
rectly, you must remember to disable the Wired sensor test.
Anemometer: manually rotate the Anemometer blades; at the same time, the control
unit will cause an upward movement lasting 5 seconds.
Sun sensor test: expose the Sun sensor to natural or artificial light; at the same time,
the control unit will cause the SUN LED to light up and there will be a downward move-
ment lasting 5 seconds. Block the Sun sensor; at the same time, the control unit will
cause the SUN LED to switch off and there will be an upward movement lasting 5 sec-
onds.
Rain sensor test: wet the sensitive part of the Rain sensor; at the same time, the con-
trol unit will cause the RAIN LED to light up and there will be an upward movement last-
ing 5 seconds. When you have completed the test, make sure you have dried the sen-
sitive part of the Rain sensor before using the control unit in its normal operating mode.
Programming: The control unit is supplied by the manufacturer with the Wired sensor
test disabled. If you wish to enable the Wired sensor test, proceed as follows: check
that the extended menu is enabled (SUN and RAIN LEDs flash alternately), use the
"SEL" button to navigate to SENSOR CODE LED when flashing and press the "SET"
button: the SENSOR CODE LED lights up and programming is complete. Repeat the
procedure to restore the initial configuration.
Important: for information on the Wireless sensor test, please refer to the Wireless sen-
sor manual.
C) T. MOT. (Automatic Movement Lock):
The control unit enables the prevention of automatic movements (Up / Down sun blind
movements on the Sun Sensor command or Automatic Sensors function), so that if a
Stop command is sent from a radio control during movement, the control unit momen-
tarily locks the Automatic movements until a new Up or Down command is sent. The
control unit is supplied by the manufacturer with the Automatic Movement Lock dis-
abled; to enable the function proceed as follows: check that the extended menu is
enabled (SUN and RAIN LEDs flash alternately). Using the "SEL" button, navigate to
T.MOT LED when flashing and press the "SET" button: the T.MOT LED lights up and
programming is complete. Repeat the procedure to restore the previous configuration.
D) WIND SPEED (Safety upward movement):
The control unit is supplied by the manufacturer with the Safety upward movement
function disabled; if you wish to enable the function, so that after 12 hours of Wind sen-
sor inactivity the control unit automatically sends a command for Safety upward move-
ment, proceed as follows: check that the extended menu is enabled (SUN and RAIN
LEDs flash alternately), use the "SEL" button to navigate to WIND SPEED LED when
flashing and press the "SET" button: the WIND SPEED LED lights up and programming
is complete. Repeat the procedure to restore the previous configuration.
E) SUN SENSOR (Sun control movement inversion):
The control unit is supplied by the manufacturer with a Sun Control = Down command
association, that is to say when the Sun sensor detects sunlight, the control unit sends
a command for downward movement. If you want the control unit to send a command
for upward movement when sunlight is detected by the Sun Sensor, proceed as fol-
lows: check that the extended menu is enabled (SUN and RAIN LEDs flash alternate-
ly), use the "SEL" button to navigate to SUN SENSOR LED when flashing and press the
"SET" button: the SUN SENSOR LED lights up and programming is complete. Repeat
the procedure to restore the previous configuration.
F) RAIN SENSOR (Rain command movement inversion):
The control unit is supplied by the manufacturer with a Rain Control = Up command
association, that is to say when the Rain sensor detects rain, the control unit sends a
command for upward movement. If you want the control unit to send a command for
downward movement when rain is detected by the Rain sensor, proceed as follows:
check that the extended menu is enabled (SUN and RAIN LEDs flash), use the "SEL"
button to navigate to RAIN SENSOR LED when flashing and press the "SET" button:
the RAIN SENSOR LED lights up and programming is complete. Repeat the procedure
to restore the previous configuration.
R
ESET
To reset the default configuration of the control unit, press the SEL and SET buttons
simultaneously; all indicator LEDs will switch on and then off again immediately.