Electronic Control Unit LRX 2214 SWR
Electronic control unit for the automation of rolling shutters and sun blinds, with option-
al Wind, Sun and Rain sensor connection and keypad/radio control operation, for indi-
vidual and centralised control.
- Mod. LG 2214 SWR :
- Mod. LRS 2214 SWR :
- Mod. LRS 2214 SWR SET:
- Mod. LRH 2214 SWR:
T
ECHNICAL DATA
- Power supply:
- Motor output:
- Operating temperature:
- Radio receiver:
- Compatible radio controls:
- Number of codes which may be stored:
- Number of Wireless Sensors which may be stored:
- Packaging dimensions:
- Container:
Without radio receiver
433,92 MHz
"Narrow Band" 433.92 MHz
"Narrow Band" 868.3 MHz
230 V~ 50/60 Hz 600 W max.
230 V~ 500 W Max.
-10 55°C
see model
12-18 Bit or Rolling Code
Max. 6
Max. 3
110 x 121 x 47 mm.
ABS UL94V-0 ( IP54 )
C
CN1 T
ONNECTION OF
ERMINAL BOARD
1: 230 V line input (Phase).
2: 230 V line input (Neutral).
3: Upward movement motor output.
4: Shared motor output.
5: Downward movement motor output.
C
CN2 T
ONNECTION OF
ERMINAL BOARD
1: Sun sensor power supply output 24 V a/c.
2: Sun sensor input "S" (NA).
3: Rain sensor input "R" (NA).
4: Shared GND Signal input / 0 V a/c output.
5: Wind sensor input "W".
6: T1 local upward movement button input (NA).
7: T2 local downward movement button input (NA).
8: Shared GND Signal input.
9: T3 general upward movement button input (NA).
10: T4 general downward movement button input (NA).
11: Earth antenna input.
12: Antenna hot pole input.
I
O
NITIAL
PERATING CONDITION
The equipment can operate using the T1 (Up) and T2 (Down) local command buttons,
the T3 (Up) and T4 (Down) general command buttons, and in conjunction with one or
more radio controls. There is no radio control code stored in the default factory setting.
OPERATIONAL DATA:
T1 – T2 Local command buttons operation:
The following type of operation is obtained by connecting the local command buttons
(normally open) for movement activation to the low voltage inputs T1 – T2:
T1 controls upward movement until the motor running time has elapsed and T2 con-
trols downward movement. If a command is sent in the same direction before the motor
running time has elapsed, the control unit will stop movement; if a command is sent in
the opposite direction before the motor running time has elapsed, the control unit will
invert the direction of the motor.
T3 – T4 General command buttons operation:
The following type of operation is obtained by connecting the general command but-
tons (normally open) for movement activation to the low voltage inputs T3 – T4:
T3 controls upward movement until the motor running time has elapsed and T4 con-
trols downward movement. If a command is sent in the same direction before the motor
running time has elapsed, the control unit will ignore the command; if a command is
sent in the opposite direction before the motor running time has elapsed, the control
unit will invert the direction of the motor.
O
M
PERATION USING DIFFERENT
Different models of radio control may be programmed: by storing one code (1 button)
a cyclic step by step operation (Up - Stop - Down) is achieved, and by storing two dif-