PROBLEMS
No water comes out of the
nozzle or flow rate is poor.,
Water leaking from under
the high pressure cleaner.
The cleaner does not deliver
hot water
In Steam mode, the burner
does not start or stops
working and the warning
light (48) is lit.
Lamp (49) flashing.
CAUSES
No water.
Clogged water nozzle.
Backflow hydraulic device fault.
Safety valve triggered.
There is not enough fuel in the
tank (warning light 44 is lit).
You have set the temperature
wanted with knob (41) but the hot
water function is not enabled with
knob (28): LED (30) is off.
The fuel filter is dirty.
The boiler's safety thermostat has
tripped.
The burner controller has tripped
(warning light 49 is lit).
Pressure above 32 bar/464 psi.
Malfunction in some temperature
control device
REMEDIES
Make sure the water mains cock is fully
open.
Clean and/or replace the nozzle as
instructed in
"ROUTINE MAINTENANCE"
Refer to the relative manual.
IF THIS HAPPENS PERSISTENTLY DO NOT
USE THE HIGH PRESSURE CLEANER BUT
CONTACT A QUALIFIED TECHNICIAN.
Top up with fuel.
Put knob (28) into position
enable hot water functioning
Follow the instructions in
MAINTENANCE" .
Leave the cleaner to cool down for a few
minutes so the safety device can reset.
SHOULD IT TRIP AGAIN, DO NOT USE THE
CLEANER AND CONTACT A QUALIFIED
.
TECHNICIAN
Put knob (28) into position , wait a
few seconds and then into position
SHOULD IT TRIP AGAIN, DO NOT USE THE
CLEANER AND CONTACT A QUALIFIED
.
TECHNICIAN
Follow the instructions in
.
IN STEAM MODE"
Use the machine only in Cold Water.
CONTACT A QUALIFIED TECHNICIAN.
.