WiFi CAPABILITY IS ONLY AVAILABLE IN IND256x TERMINALS SO CONFIGURED AT THE FACTORY.
1.6.2.
Product Date Code
The manufacturing date or the date code for the terminal can be found on the serial data plate (on
the top of the enclosure).
The serial number will begin with a letter and a number (for example B212000371). The letter
represents the first three digits of the year per the date code chart in Table 1-3 (the letter "B" in our
example represents "201x") and the number is the unit's digit of the year (the number "2" in our
example). So, "B4" decodes to the year 2014.
1.6.3.
Connections
The following figure shows the connection locations on the back of the harsh enclosure.
Power input
Power input
COM1 (standard)
COM2 (optional)
1-8
METTLER TOLEDO IND256x Weighing Terminal Installation Manual
Table 1-3: Current and Later Date Code Formats
Date Code
A
B
C
D
E
COM3, optional
COM2, optional
Figure 1-2: IND256x Connection Port Locations
AC power supply 220V (187-250V 50/60Hz) input (ATEX & IECEx version)
or
DC power supply 24V(18V-30V) input (ATEX & IECEx version)
or
external Ex battery
intrinsically safe RS232
intrinsically safe analog 4-20mA output
(factory-configured only)
NOTICE
Year
Date Code
200x
F
201x
G
202x
H
203x
J
204x
K
COM, Reserved
or
Year
205x
206x
207x
208x
209x
COM1, standard
Weighing
platform
Wi-Fi communication module
30491430