7. Servicing the product

Always use original accessories from Grundfos to
ensure safe and reliable operation.
WARNING
Electric shock
Death or serious personal injury
- Before starting any work on the product,
make sure that the power supply has
been switched off and that it cannot be
accidentally switched on.
Maintenance and service must be carried
out by specially trained persons and
according to local regulations.

7.1 Maintenance

If the power supply cable is damaged, it
must be replaced by the manufacturer, the
manufacturer's service partner or similarly
qualified person.
The Conlift does not require any special
maintenance, but we recommend that you check
operation and pipe connections at least once a year
and that you clean the collecting tank, if necessary.

7.2 Service

Thanks to the Conlift design, service can easily be
performed in case of malfunction or blocked pump.
Electrical connection must be carried out
by an authorized electrician.
WARNING
Electric shock
Death or serious personal injury
- Before starting any work on the product,
make sure that the power supply has
been switched off and that it cannot be
accidentally switched on.
7.2.1 Conlift
See illustrations on page 202.
Make the following checks and clean the collecting
tank, if necessary:
1. Disconnect the power supply.
2. Cut off the flow of condensate from the boiler or
other application, or stop the flow of condensate
to the Conlift.
3. Make sure that the hoses are not mechanically or
chemically damaged.
4. Remove the outlet hose by turning the bayonet
coupling, and check the O-ring. The condensate
in the hose will not run out due to the non-return
valve.
5. If the condensate is running out of the hose,
check and clean the non-return valve.
6. Press the side-locking catches and lift off the
motor support. Place it in upright position.
7. Remove deposits, dirt, algae and incrustations
under running water.

7.3 Contaminated products

If a Conlift has been used for a liquid which is
injurious to health or toxic, it will be classified as
contaminated.
CAUTION
Biological hazard
Minor or moderate personal injury
- Flush the product thoroughly with clean
water and rinse the parts in water after
dismantling.
The product will be classified as contaminated if it
has been used for a liquid which is injurious to health
or toxic.
If you request Grundfos to service the product,
contact Grundfos with details about the liquid before
returning the product for service. Otherwise,
Grundfos can refuse to accept the product for
service.
Any application for service must include details
about the liquid.
Clean the product in the best possible way before
you return it.
Costs of returning the product are to be paid by the
customer.