Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Niko 10-286 Produktinformation

Modulare außenstation (vormontiert, 3 modulen, 4 modules)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.2. If the problem is not solved, go through the following list of possible problems:
Problem
You hear a negative tone on the
external unit.
The image on the internal video
unit is not clear.
No image appears on the internal
video unit. Other functions are
working properly.
6.3. Replacing the external unit
All programmed data such as serial numbers and parameters are stored in the EEPROM. If the external unit needs to be replaced, the EEPROM storage can be
removed from the programmed external unit and installed into the new, comparable external unit. This is done as follows:
1. Open the housing.
2. Disconnect the display from the power supply: pull off the connection socket.
3. The EEPROM storage is located in the electronic part of the display module. Remove the EEPROM storage.
4. Click the EEPROM into the new external unit (display module).
Ensure that the electronic components are aimed towards you when placing the EEPROM.
5. Reconnect the external unit to mains voltage.
6. The data is automatically copied onto the EEPROM.
7. If the data transfer was unsuccessful, hold down all 3 smart keys at once until the device restarts (after approx. 10 s).

7. TECHNICAL DATA

Reference code
Dimensions flush-mounting box 10-286
Dimensions flush-mounting box 10-386
Dimensions front plate 10-286
Dimensions front plate 10-386
Power supply voltage
Material front plate
Material flush-mounting box
Material modules
Weight: 10-286
Weight: 10-386
Colour
Protection degree
Video signal
Allowable ambient temperature
Marking
EN
Cause
There is an error in the programming.
The system is still in programming mode.
The internal video unit is not connected correctly.
Conductors V1 and V2 have been reversed.
Incorrect cable:
• cable distance is too great;
• cable cross-section is too small;
• cable is not a twisted pair cable.
The wiring is not correctly configured:
• M or P is missing;
• V1 or V2 is not connected.
10-286 (without camera)
10-386
420 mm x 180 mm x 50 mm (H x W x D)
540 mm x 180 mm x 50 mm (H x W x D)
440 mm x 200 mm x 3 mm (H x W x D)
560 mm x 200 mm x 3 mm (H x W x D)
24 Vdc ± 8 %
Stainless steel
Steel zinc-coated
Anodized aluminium
2780 g
3480 g
Alu/black
IP44
1 Vpp, symmetrical
-20°C tot +50°C
CE marking
Solution
Delete the programming and perform again.
Exit programming mode.
Check the wiring.
Reverse conductors V1 and V2.
Replace the current cable with a suitable cable.
Check the wiring (see fig. 1 wiring diagram).
10-286 / 10-386
41

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

10-386

Inhaltsverzeichnis