Niko 10-286 Produktinformation Seite 37

Modulare außenstation (vormontiert, 3 modulen, 4 modules)
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10-386
Cable diameter
0,5 mm (UTP)
0,6 mm (bv. TPVF)
0,8 mm (bv. SVV, TVVF, JYSTY, ...)
Which power supply do I use?
Power supply
10-801
10-801 + 10-805-01
Note:
1. If the external units are called simultaneously, please note that the address of the external units must be set.
2. Contact Niko for larger installations.
Voeding
*10-806
**10-801 + 10-805-01
* For smaller installations use video splitter 10-821-01.
** For larger installations use video splitter 10-822-01.
Note:
1. If the external units are called simultaneously, please note that the address of the external units must be set.
2. Contact Niko for larger installations.
3.2. Connection and mounting
Step
1. Connection
2. Installation of flush-mounting
box
3. Cabling
4. Connection of a bell push button
(05-540)
5. Mounting sealings
EN
Maximum distance
45 m
65 m
115 m
Max # 10-505
90
(maximum 3 devices in parallel)
130
Max # 10-575
Max # 10-576
10
12
-
-
-
-
-
-
120
60
-
-
Action
• 10-286
Connect the unit according to the wiring diagram (fig. 1).
• 10-386
Connect the unit according to the wiring diagram (fig. 2).
Use the cable openings foreseen in the flush-mounting
box to wire the external units.
Tighten the surface-mounting box using 4 (10-286) or 6
(10-386) screws (fig. 3).
The 10-286 requires a 3-wired connection, the 10-386
requires a 6-wired connection.
The cabling between the modules (fig. 4).
Connect the bell push button to the terminals E and P (fig.
1 & fig. 2).
• Install the included sealing to the front plate. Firstly, cut
the upper sealing into the right size before sealing off
the sides (fig. 5a).
• To prevent condensation, do not seal the bottom of the
front plate.
Max #10-520
60
(maximum 2 devices in parallel)
130
Max #10-570
Max #10-570, 10-572
of 10-573
-
-
60
-
50
-
40
-
-
-
-
70
TIP
Disconnect all power before installing the internal unit.
Do not connect the device to the mains voltage until
installation has been completed.
• Mount the flush-mounting box completely level with
the wall.
• Place the camera at a 160 to 170 cm height.
(Not included: screws to mount the flush-mounting box)
Keep in mind the maximum distance between the power
supply and the internal or external unit.
Remove the lamp from the bell push button to prevent
the power from being continuously used, making calls no
longer possible.
Cut the included sealing 1 mm shorter than the width of
the front plate; the sealings must be 0.5 mm off the edge
(fig. 5b).
10-286 / 10-386
Max # external units 10-286
1
5
Max # external units 10-386
1
1
3
5
5
5
37