Operation

Overview DMX parameters
Two channels are required for controlling the pump. The first channel is defined via the OASE DMX controller. The se-
cond channel is incremented and defined automatically.
• The first possible DMX starting address is 1.
• The last possible DMX starting address is 511.
Channel
DMX Channel + 0
DMX Channel + 1
Reset error
How to proceed:
1. Use DMX Channel + 0 to set a value between 240 and 255.
2. Use DMX Channel + 0 to set a value between 0 and 10.
– The error has been reset.
3. Access the pump with the desired value.
Information on show programming
Switch-on/switch-off cycles
• Only switch on the pump max. 1 x per minute.
• Wait for at least 10 seconds between switching off the pump and switching it on again.
Switch-on sequence:
Step
Description
1
Pump rotational speed set to minimum
2
Control mode ON
3
Waiting time 1-3 seconds
4
Effect
Switch-off sequence:
Step
Description
1
Pump rotational speed set to minimum
2
Pump OFF
The DMX-Channel + 0 (Control Channel) may not be changed during a show. The effects are exclusively programmed
via the DMX-Channel + 1 (Speed Channel).
Addressing via DMX/RDM
RDM (Remote Device Management) is an open and bi-directional protocol standard for DMX-controlled devices. The
permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (message) is
sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer (semi-
duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several subscribers from
answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chang-
ing the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
22
Description
Pump OFF
Control mode (do not use)
Speed control
Speed control, characteristic line compensation
Not in use
Reset error (→ Reset error)
Speed default value
Value
0 ... 10
11 ... 49
50 ... 99
100 ... 149
150 ... 239
240 ... 255
0 ... 255
Channel
DMX Channel + 1
DMX Channel + 0
DMX Channel + 1
Channel
DMX Channel + 1
DMX Channel + 0
Values
0
50 ... 99
1 ... 255
Values
0
0 ... 10