Herunterladen Inhalt Inhalt Diese Seite drucken

Oase Varionaut 90 24V/DMX/02 Gebrauchsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connecting the unit to the power supply
• Switching power pack requirements:
– Electronic switching power pack with DC decoupling between the primary and secondary side.
– Output voltage: 24 V DC
– Residual ripple: Max. 5 %
How to proceed:
 G
• Fasten the PowerBox 24V DC to a suitable foundation using 2 screws.
 H
1. Remove the protection cap from PowerBox 24 V DC.
– The two 24 V DC sockets are connected in parallel. The second 24 V DC socket can be used for supplying other
units (signal feed-through).
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
 J
• Connect the PowerBoxes with each other (loop).
– Use the OASE 24 V DC/01 connection cable.
– Do not exceed the max. permissible current for the connection method/system. (→ Technical data)
Commissioning/start-up
N O T E
Never allow the pump to run dry. Otherwise the pump will be destroyed.
• Ensure that the pump is always flooded during operation.
• Regularly check the water level.
N O T E
• A DMX controller or a DMX/RDM controller can be used for commissioning/start-up and operation.
• The DMX / RDM protocol is used for signal transmission and control.
• For programming, refer to the controller documentation.
Switching on the unit
Switching on:Establish an electrical connection and transmit the DMX control signal.
Switching off: Transmit the DMX control signal and disconnect the electrical connection.
Addressing via DMX
DMX (Digital Multiplex) is a standardised digital transmission protocol used in stage and event equipment as well as in
many Oase components.
The DMX Channel and the mode can be changed by means of a DMX controller from OASE. Read the corresponding
operating instructions.
Description
Serial No. (SN)
Product ID
Version No.
DMX Channel
Configuration mode
Config. mode
1
Value
Enter the unit serial number. The serial number  is indicated on the label next
to the type plate.
120
1
The factory-set DMX channel  is indicated on the label next to the type plate.
1 = Set DMX starting address.
Description config. mode
Set DMX channel
Transfer value
Description transfer value
Function
x
Speed
- EN -
x + 0
x + 1
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis