– Power the Inverter using a cable:
- FROR4 G2,5 450 / 750V for RS 68/EV
- FROR4 G4 450 / 750V for RS 120-130-160-200-250-300-
400/EV
- FROR4 G6 450 / 750V for RS 500
- FROR4 G10 450/750V for RLS 500
- FG70R 4G10-0.6/1kV for RS 650-800/EV and
RLS 650-800/EV
- FG70R 4G16-0.6/1kV for RS 1000-1200/EV and
RLS 1000-1200/EV
– Thread the cable through the specific hole below the Inverter
itself;
(see Fig. 6 for RS 68-120-130-160-200-250-300-400-500/EV
and RLS 500/EV , Fig. 8 and Fig. 9 for RS 650-800-1000-
1200/EV).
– Connect the inverter signals to the burner terminal strip with a
shielded cable type:
FROR 2R 5 x 0.5 300 / 500V, (see Fig. 7, Fig. 8, Fig. 9 and
Fig. 10).
– Shield as shown in Fig. 5 for RS 68-120-130-160-200-250-
300-400-500/EV and RLS 500/EV.
– Shield as shown in Fig. 3 and Fig. 9 for RS 650-800-1000-
1200/EV.
RS 68-120-130-160-200-250-300-400-500/EV
RLS 500-650-800-1000-1200/EV
D8179
RS 68-120-130-160-200-250-300-400-500/EV
RLS 500-650-800-1000-1200/EV
Communication with LMV
Installation
INVERTER power supply
Fig. 6
D8191
Alarm
Fig. 7
7
RS 650 - 800 - 1000/EV
RS 650 - 800/EV
RLS 650 - 800 - 1200/EV
Communication with LMV
Alarm
power supply
INVERTER
RS 650 - 800 - 1000/EV
RLS 650 - 800 - 1200/EV
power supply
INVERTER
Alarm
GB
Motor cable
Communication
Motor cable
with LMV
Fig. 8
Fig. 9