AVENTICS | LS04 SW | R412009675–BAL–001–AD | English
Establishing the electrical connection
3
1. Open the spring clamp by lightly pressing and holding
down the button, and insert the stripped end of the wire
into the clamp.
Note the markings identifying the connections for
solenoids 12, 14 and 0.
2. Release the button.
The cable end is now secured by the clamp spring
force and the electrical connection is complete.
Breaking the internal contacts
4
The neutral wires for the valve plates are connected
internally. This connection can be interrupted to obtain
neutral sections that are independent of each other.
How to break the internal contacts:
1. Remove the valve plate where the interruption should
start (see "Assembly" on page 2).
2. Break off the contact lug (see
3. Replace the valve plate.
Blanking, partition and supply plates break the
internal contacts.
6

Maintenance

The P-assembly strip is maintenance-free. Please contact
the service department at AVENTICS if you have any
technical problems.
7

Cleaning and servicing

Damage to the surface caused by solvents and
aggressive detergents
The surfaces and seals could be damaged by
aggressive solvents and cleaning agents.
O Never use solvents or aggressive detergents.
How to clean the VS LS04 SW:
1. Make sure that all relevant system parts are not under
voltage or pressure.
2. Clean the VS LS04 SW with a damp cloth. Only use
water or a mild cleaning agent.
8
Disposal
O Dispose of the VS LS04 SW in accordance with the
applicable national regulations.
4
).
CAUTION
9

Technical data

General
Pneumatic
Push-in fitting for plastic tubing with
connections
external Ø:
1, 3/5: 10 mm (3/8"), 2, 4: 4 mm (1/8") or
6 mm (1/4")
X (external pilot control air): 6 mm (1/4")
R (restricted pilot exhaust air): 6 mm
(1/4")
Internal or
Via different end plates,
external pilot
connection X closed with internal pilot
control
control
Stages of
2 to 24 valve stations for 2 to 24 valve
expansion
solenoids
Mounting
Any
orientation
Ambient
–10 °C to +50 °C
temperature
Pneumatics
Medium
Compressed air in accordance with ISO
8573-1:2010.
Max. particle size 5 μm, the pressure
dew point must be at least 15 °C under
ambient and medium temperature and
may not exceed 3 °C, oil content 0 mg/
3
m
– 5 mg/m
(oil: OL 1413-068, AVENTICS no.
5 962 260 000, trade name per
AVENTICS standard N28, Volume 8:
Shell Oil 4007)
Medium
–10 °C to +50 °C
temperature
Nominal flow 320 l/min at 6 to 5 bar
Working
–0.9 to 8 bar
pressure
Control
3 to 8 bar
pressure
range
Electrics for solenoid coils
Rated
24 VDC ( 10%)
solenoid
from a power pack with safe isolation
voltage
according to DIN EN 60742,
classification VDE 0551
Power
0.7 W incl. LED and protective circuit
consumption
per solenoid
Operating
Continuous operation (S1)
mode
according to
VDE 0580
3
.