MAINTENANCE

Thanks to the self-cleaning pre-filter, the HYDRA RAINMASTER can provide long-last improved perfor-
mance if maintenance is correctly and regularly performed following the instructions indicated in ROU-
TINE MAINTENANCE and EXTRAORDINARY MAINTENANCE.
ROUTINE MAINTENANCE
Self-cleaning pre-filter:
clean the filter cartridge in counter-current by opening the drain valve for 15/20 seconds. Washing in
counter-current is performed as indicated in the TECHNICAL SPECIFICATIONS.
If the cartridge is not perfectly clean after washing, repeat the operation with the same procedure one
or more times until the desired cleanliness is reached. If acceptable cleanliness is not achieved for
good filter operations, follow the extraordinary maintenance procedure described below.
Carbon filters:
- replace the CB-EC cartridge at least every 6 months or before the limit if odours, colours or bad
tastes are found in water and/or flow significantly reduces;
- replace the LA cartridge at least every 3 months or before the limit if odours, colours or bad tastes
are found in water and/or flow significantly reduces.
Post-filter (HYDRA RAINMASTER TRIO models only):
- replace the post-filter cartridge FA every 3-6 months when replacing the active carbon cartridge
or before the limit if flow significantly reduces.
NB: Dispose of used cartridges according to current laws.
EXTRAORDINARY MAINTENANCE
Self-cleaning pre-filter:
in time, routine cartridge cleaning may become difficult due to build-up on the cartridge net. In this
case, extraordinary cartridge cleaning is required as follows:
- cut off water flow upstream from the filter;
- release filter pressure by opening the water tap downstream from the filter;
- open the filter unscrewing the cup from the head using the spanner (supplied);
- remove the cartridge (wearing protective gloves to prevent scratches due to worn mesh);
- clean the cartridge under a jet of cold water and use a soft brush to remove most impurities;
- insert the clean cartridge in the cup;
- screw the cup onto the head;
- follow the procedure under "FIRST USE" to reuse the filter;
- replace the self-cleaning filter cartridge every 24-36 months or before the limit if the cartridge
net is visibly torn.
Carbon filters and post-filter:
In the event of prolonged filter disuse, disconnect the device from the mains and remove cartridges,
storing them in a cool and dry place until next use.

TROUBLESHOOTING

HYDRA RAINMASTER filters are constructed following strict quality controls and are subject to stringent
efficiency and resistance tests. Following are a series of problems that may occur due to incorrect in-
stallation or maintenance or improper use, possible negligence or due to filter or part wear.
PROBLEM
Water does not run from
faucets
Unfiltered water runs from
faucets
The cartridge does not clean
during self-cleaning operation
Water leaks between the filter
head and bowl.
Water leaks from connections
between pipes and from the
sides of the filter
Water leaks between the bowl
and drain valve
DECLARATION OF COMPLIANCE
Manufacturer's address: ATLAS FILTRI srl - Via del Santo 227, 35010 Limena (PD) - ITALY
HYDRA RAINMASTER filters are constructed in accordance with the following European directives:
UNI EN 1717 - Protection against pollution of potable water in water installations and general require-
ments of devices to prevent pollution by backflow.
CAUSE
- cartridge clogged;
- Bowl broken;
- cut-off valves and/or By-
pass closed.
- cartridge broken;
- spring broken;
- cartridge gasket
ruined;
- by-pass valve open.
- insufficient pressure
in the bowl;
- cartridge not correctly
positioned in the
bowl.
- Bowl O-ring ruined
®
- sealant (TEFLON
)
insufficient
- drain valve gasket
damaged
SOLUTION
- clean the cartridge following
the extraordinary
maintenance procedure;
- replace the bowl and O-ring;
- open the closed cut-off valve
or by-pass.
- replace the cartridge;
- replace the spring;
- replace the cartridge gasket;
- close the by-pass valve.
- check the drain pipe: if
pinched or bent, remove the
problem;
- rotate the cartridge
clockwise or Counter-
clockwise so that it moves
vertically without strain in
the bowl.
- replace the O-ring.
- add a few turns of TEFLON
- replace the gasket.
®