5.2. FAULTS
SYMPTOMS
COMPRESSOR NOT
STARTING
POOR PERFORMANCE
OR OVERHEATING OF
COMPRESSOR
PROBABLE CAUSE
Compressor protection cutting in
Electrical problems
Component problems
Improper use of the appliance
Fault on the cooling circuit
CHECKS
Closely-spaced starts do not give time
for pressure to re-balance:
Check that the food in the compartment
is not hot or full of water
Check the state of the gaskets and the
number of times the doors are opened
The refrigeration unit is not operating
properly: check loading of the circuit in
general and the compressor in particular
Power supply voltage is outside the
admitted range
The compressor terminals are not live;
check the connections and the state of
the contacts upstream from the motor.
Compressor has mechanical faults
Winding split or burnt
Type of load: check that the food is not
placed in the compartment hot or full of
water.
Compartment doors: check the state of
the gaskets and the number of times the
doors are opened
Incoming air is insufficient; check the
flow through the air grilles
The amount of cooler is no longer
sufficient: check pressure for suction and
delivery and look for leaks on the circuit.
Compressor
has
mechanical output: check pressure for
suction and delivery.
problems
of