PROVISIONS FOR INSTALLATION
Place (fig. 6 – p. 4)
It is advisable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 50 mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.

Installation

Installation operations, gas or voltage conversions to other than the original, starting up the
installation or appliance, ventilation, letting out fumes, and maintenance must be done following the
manufacturer's instructions and observing the norms in force, by qualified personnel, in compliance
with the following provisions (GB):
 Gas Safety (Installation and Use) Regulations, 1984
 Health and Safety at Work Act, 1974
 Codes of Practice, BS6173, 1982
 The Building Regulations, 1985
 The Building Standards Regulations, 1981
For others countries follow the relevant local rules for:
 Gas board rules
 Building regulations and local fire prevention provisions
 Safety norms in force
 Provisions of the Gas supplying company
 The Electrical Norms in force
 The Fire Brigade rules
Fumes evacuation
Type "A1" gas appliances
The appliances are type A1 gas appliances and it is not necessary to connect them directly to an
evacuation pipe for combustion products. The products of combustion, however, have to be directed
into suitable hoods or similar devices, connected to a reliably efficient chimney, otherwise directly
outside. If these devices are not available, it is possible to use an extractor fan connected directly to
external environment with a capacity no lower than what is stated in table 1. This value has to be
increased with the air exchange necessary for the operators' well-being in accordance with the
3
norms in force (approximately a total of 35 m
/h per kW of gas output installed).
INSTALLATION
Preliminary operations
Remove the appliance from the packaging, ensure that it is intact and, if in doubt, do not use it but
contact professionally qualified personnel. The packaging materials are compliant with environmental
safety regulations. They can be stored without risk, or else should be disposed of in accordance with
current national regulations, particularly those regarding the nylon bag and the polystyrene.
After verifying that the appliance is in good conditions, the protective film may be removed. Clean
the external parts of the appliance carefully with warm water and detergent, using a cloth to remove
all remaining residues and then dry it with a soft cloth. If there are still traces of glue, these can be