Duration: 6s
5.
____ IDLE ____
XXXXXXXXXX
6.
Vxxx Fxxx Ixxx Dxxx
7. And so on, you could adjust the volume and fan speed;
XXXXXXXXXX
8.
____ IDLE ____
XXXXXXXXXX
9.
____ IDLE ____
• If the interval is set to a nonzero value (5s-250s), the timer is started.
• When executing timing fogging, if the interval is set to zero, will
automatically be converted to continuous fogging.
DMX Control Operation
1. Setting DMX mode and DMX address by function buttons (figure 1-E) under
the LCD display, DMX operation has not started at this time;
DMX Mode: 1ch
2.
____ IDLE ____
DMX Address: 2
3.
____ IDLE ____
4. Connect the DMX 512 controller cable to the input socket (figure 1-G or I)
of the machine unit. Make sure the signal cable polarity is correct. When
DMX socket receives effective DMX signals, the machine enter DMX control
mode automatically, other built-in functions invalid;
©Copyright LOTRONIC 2018
Press "Up" or "Down" to adjust time value of
duration (5s - 250s);
After setting the interval and duration, press
START/STOP to start timing fogging, the main
display information as shown on the left;
Press again START/STOP to stop Timing fogging.
Please note the machine design of machine
stops working after a delay of 30 seconds,
automatically clear the tubing of the remaining
liquid, at this point, IDLE will blink;
After the Self-cleaning process is complete, IDLE
will stop blinking.
Press MENU enter to DMX mode, press Up or
Down button to set the DMX Mode, there are 3
DMX modes for choice:1CH, 2CH, 4CH;
Press MENU enter to DMX address, press Up or
Down button to set the DMX address;
12