Technical Information

Reference Signal

The following diagram shows the reference signal
block.
SYNC
IN
75 Ω
SYNC
OUT
75 Ω
Switches
automatically
When VS singal is input from the SYNC IN
terminal
The signal input from the SYNC IN terminal is output
to the SYNC OUT terminal.
Sync signal detection
75 Ω
INT
LL
SW501
When no signal is input from the SYNC IN
terminal
The internal reference signal or the line-lock reference
signal is output from the SYNC OUT terminal.
Use the slide switch SW501 inside the front panel to
determine the type of the signal to be output from the
SYNC OUT terminal.
Set the SW501 as follows:
INT : to output the internal reference signal
LL : to output the line-lock reference signal
Factory preset position is "INT."
INT
LL
SW501
13(EN)