Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

OPERATION

Call from the door station
When a call is made from the external station,
the videointercom speaker receives the rings
(according to programming), the green LED
starts flashing and the calling user is displayed
on the screen for around 30 seconds. Also the
red LED flashes if the ring has been deactivated.
If the call time has expired and the
videointercom has turned OFF, press the
button "
" to reconnect with the calling
external station.
To start the conversation with the external
station for once of around 90 seconds, press
the
button; the green LED goes ON.
If it is desired to disable the audio to the door
station, but continuing hearing the audio from
the door station press shortly the button
this status the red LED will light up continuously.
To restore the audio to the door station press
again the button
; the red LED will recover
the previous status.
In case of a call to a user with more than one
videointercom in parallel installed in the apart-
ment, all the videointercom will ring, but only
the videointercom with internal address 000
will turn on. You can answer from this
videointercom by following the instructions
above. From others videointercoms it is pos-
sible to answer by pressing button
operation will automatically turn ON this
videointercom and will turn OFF the intercom
that had been turned ON before. If, before
answering, you wish display who is ringing,
press the button
and then the button
To operate the electric door lock release press
the button
.
To end the communication and switch OFF the
video intercom press the button
The video intercom switches OFF automatically
when the communication time expires.
Monitor function and connection with one
or more external stations.
With the system in stand-by and no
conversation in progress, it would be possible
to monitor the external door stations by pressing
on the videointercom the button
buttons previously programmed for this
function.
If the installation includes more external stations
and button " " is programmed correctly, you
can monitor the external stations (max. 4) in
sequence by pressing the same button again
and again.
The videointercom will be turned ON for about
30 seconds. The monitoring will be interrupted
in case of request of monitor service by
another user, call between users or from an
external station.
Pressing the button
while monitoring,
automatically the communication with the
external door stations is enabled.
If after pressing the button
remains switched-OFF and a busy tone is
heard, another conversation is in progress
and it is necessary to wait until the system
becomes free.
Making or receiving a call from another
user.
When the installation is in stand-by, you can
make a call to another user. You must have
stored the address of the desired user's in the
numerical buttons.
Before making a call press the button
you get a busy tone, wait until the system
becomes free; if you get a free tone it is
possible to make a call by pressing the proper
button. After pressing the button you will get
a calling tone on the loudspeaker, while the
videointercom of the called user rings (without
switching-ON) with the programmed melody.
If the called user answers within 30 seconds,
a 90-second conversation starts, otherwise
; in
the system goes back to free.
The internal conversation in progress will be
automatically interrupted in case of call from
external station to any other user.
Making or receiving an intercom call in
your apartment.
When the system is in stand-by it would be
possible to make a local intercommunicating
call to all the videointercoms installed in the
apartment (max 6 monitors with internal
address from 000 to 005) by pressing buttons
. This
previously programmed with code 000.
Before making the internal call press the
button
, if you get a busy tone wait until the
system becomes free; if you get a free tone
it is possible to make an internal call by
.
pressing the proper button. After pressing the
button you will get a calling tone on the
loudspeaker, while the videointercom of the
called user rings (without switching-ON) with
the programmed melody. If the called user
.
answers within 30 seconds, a 90-second
conversation starts, otherwise the system
goes back to free.
The internal conversation in progress will be
automatically interrupted in case of call from
external station to any other user.
or the other
the monitor
Tone table
Tone of pressure of a button.
indicate the pressure of the numerical buttons,
and
.
0
1
2
Acknowledge tone.
programming phase to indicate a valid operation.
; if
0
1
2
Tone of system ready.
if the system is free
0
1
2
Calling tone.
It is activated during a call to another
user or during an intercommunicating call (active
for 30 seconds or until the called user answers).
0
1
2
Busy tone.
Indicates that the line is busy
0
1
2
Dissuasion tone.
nonexistent device is call or when a device is not
available.
0
1
2
End conversation tone.
before the conversation time ends.
0
1
2
Calling table
1
DIN-DON
2
DRING1
3
DRING2
4
DRING3
5
DRING4
6
MELODY1
7
MELODY2
8
MELODY3
9
MELODY4
10 MELODY5
11 MELODY6
12 MELODY7
13 MELODY8
14 BEEP
Note . All the acoustic signalling, with the
exception, of the system ready and calling tone
last after about 2 seconds.
It is activated to
3
4
5
It is activated during the
3
4
5
Activated for 30 seconds
3
4
5
3
4
5
3
4
5
It is activated when a
3
4
5
It is activated 10 seconds
3
4
5
Mi 2424
- 20 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eh9262agctEh9262ctEh9262cw

Inhaltsverzeichnis