Caution, welding in small work areas requires surveillance from a safe distance. In addition, the welding of certain
materials containing lead, cadmium, zinc, mercury or beryllium may be particularly noxious.
Do not weld in areas where grease or paint are stored.
FIRE AND EXPLOSIONS RISKS
Protect the entire welding area. Compressed gas containers and other inflammable material must be
moved to a minimum safe distance of 11 meters.
A fire extinguisher must be readily available at all times.
Be careful of spatter and sparks, even through cracks.
They can be the source of a fire or an explosion.
Keep people, flammable objects and containers under pressure at a safe distance.
Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any
inflammable or explosive materials (oil, petrol, gas...).
Grinding operations should not be directed towards the device itself or any flammable materials.

ELECTRIC SAFETY

The machine must be connected to an earthed electrical supply. Use the recommended fuse size.
An electrical discharge can directly or indirectly cause serious accidents, or death .
Never touch live parts inside or outside of the device when it is powered on (Torches, clamps, cables, electrodes) as they
are connected to the welding circuit.
Before opening the device, it is imperative to disconnect it from the electrical supply and wait 2 minutes so that all the
capacitors are discharged.
Do not touch the torch or electrode holder and earth clamp at the same time.
Be sure to change the cables and torches if they are damaged, to be performed by qualified and authorized personnel.
Ces accessoires doivent correspondre à la machine (taille, puissance...)
Always wear dry clothes in good condition, in order to be insulated from the electrical circuit. Wear insulating shoes,
regardless of the environment in which you work in.
EMC CLASSIFICATION
These Class A devices are not intended to be used on a residential site where the electric current is
supplied by the public network, with a low voltage power supply. There may be potential difficulties in
ensuring electromagnetic compatibility on these sites, because of the interferences, as well as radio
frequencies.
This equipment does not comply with IEC 61000-3-12 and is intended to be connected to private
low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. On
a public low-voltage power grid, it is the responsibility of the installer or user of the device to ensure,
by checking with the operator of the distribution network, which device can be connected.
This equipment complies with IEC 61000-3-11 if the power supply network's impedance at the electircal
installation's connection point is inferior to the network's maximum admissible impendance Zmax as
specified in the following table :
Reference
Zmax admissible
ELECTROMAGNETIC INTERFERENCES
The electric currents flowing through a conductor cause electrical and magnetic fields (EMF). All wel-
ders should use the following guidelines to minimize exposure to the welding circuit's electromagnetic
fields:
The EMF fields may disrupt some medical implants, such as pacemakers. Protection measures should
be taken for people wearing medical implants. For example, access restrictions for passers-by or an
individual risk evaluation for the welders.
8
100P 130P 160P 200P
100P
0.34 Ohms
0.34 Ohms
130P
160P
0.34 Ohms
EN
200P
0.25 Ohms