MENU 2 – DISPLAY
MENU 2.1 – DISPLAY NIGHT MODE
Night mode
Setting: On/Off
You can activate night mode here.
Schedule night mode
Setting: 00.00 – 00.00
If you have activated "Night mode", you can set the
required time interval for "Night mode" here.
MENU 5 – LICENCES
You can find licences for open source code here.
MENU 9 – INSTALLATION
MENU 9.1 – RMU S40 FOR CLIMATE SYSTEM
Controlling the system
Setting: 1 – 32
Here you set which system or zone the relevant room
unit is to control.
Address RMU S40
Setting: 1 – 8
Communication address for the unit.
30
Disturbances in
comfort
MANAGE ALARM
In the event of an alarm, some type
of malfunction has occurred, which is
indicated by the status lamp shining
with a steady red light. A dialogue box
appears in the display, containing in-
formation about the alarm.
ALARM
In the event of an alarm with a red
status lamp, a malfunction has oc-
curred. The display shows what type
of alarm it is and lets you reset the
alarm.
In many cases, it is sufficient to se-
lect "Reset alarm" for the installation
to revert to normal operation.
If the red lamp goes out after select-
ing "Reset alarm", the alarm has been remedied.
It the red light is still on or if the alarm recurs, the cause
of the problem remains.
"Auxiliary operation" is a type of emergency mode. This
means that the installation attempts to produce heat
and/or hot water, even though there is some kind of
problem. This could mean that the heat pump's com-
pressor is not in operation. In this case, any electric ad-
ditional heat produces heat and/or hot water.
Caution
To select "Auxiliary operation", an alarm action
must be selected in menu 7.1.8.1 – "Alarms"
in the main product.
Caution
Selecting "Auxiliary operation" is not the same
as correcting the problem that caused the
alarm. The status lamp will therefore remain
red.
TROUBLESHOOTING

COMMUNICATION ERROR

• Check that the cable is correctly connected between
RMU S40 and the main product.
• Check that the addresses in the room unit's "Installa-
tion" menu and the main product's 7.2.1 menu corres-
pond.
ALARM
12
Alarm
Reset alarm
Activate auxiliary operation
Heating
Alarm
Below is a brief description
of the alarm, as well as
proposed actions.
Show more information