Installation procedure
(with springs)
Installation procedure
(with fixing brackets)
CONNECTING TO THE POWER MAINS
Wiring diagram
Worktop must be absolutely horizontal;
•
Seal the cut surfaces with a suitable sealant to avoid swelling caused by moisture. The
•
sealant must be heat resistant;
Put the supplied springs in their places;
•
Feed the mains connection cable down through the cut-out;
•
Insert the appliance into the cut-out;
•
Press the appliance firmly towards the worktop from above.
•
Worktop must be absolutely horizontal.
•
Seal the cut surfaces with a suitable sealant to avoid swelling caused by moisture. The
•
sealant must be heat resistant.
Feed the mains connection cable down through the cut-out.
•
Insert the appliance into the cut-out.
•
Centre the appliance in the cut-out.
•
Fix the appliance to the worktop by means of the brackets and accessories provided.
•
Holes are provided in the bottom of the tray where you can attach the screws C that
hold the brackets B in place.
The appliance may ONLY be connected by an authorized qualified technician.
•
Electric system protection should comply with all relevant regulations.
•
The connection clips can be accessed when the connection clip covers are opened /
•
removed.
Before connecting the appliance, make sure the voltage indicated on the rating plate is
•
consistent with the voltage in your home network. Connection voltage should be
checked by a qualified technician using a corresponding measuring device!
The rating plate with basic information is attached on the lower side of the appliance.
•
In order to make a fixed connection to the mains, insert an all-pole circuit breaker
•
between the appliance and the mains. This device shall have a contact separation in all
poles, providing full disconnection under overvoltage category III conditions.
The current conducting and isolated parts must be protected from any possibility of
•
direct contact.
WARNING!
Before any intervention, disconnect the appliance from the power mains. Connect the
•
appliance in compliance with the electric connections diagram supplied; make sure the
relevant network voltage is observed!
The ground wire should be connected to the clip indicated by the earth symbol.
•
The mains cable should be fed through the fastening clip which protects it from being
•
accidentally pulled out.
After connecting the appliance, turn on all cooking zones / heaters for approximately
•
three minutes to make sure they are operating correctly.
Incorrect connection may destroy parts of the appliance, making the warranty void.
•
Connection cable on the back of the appliance should be led in such way that it does
•
not touch the appliance back wall, as this part will get very hot during operation.
The following cables must be used for connection:
2
H05RR-F , 3x0,75mm
•
2
H07RN-F , 3x0,75mm
•
H05V2V2-F , 3x0,75mm
•
LIVE
L
BROWN
EARTH
GREEN / YELLOW
NEUTRAL
N
BLUE
2
7