Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Informations - Gorenje 426150 Gebrauchsanweisung

Gasherd
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65
Conversion to another
type of gas
(only with some models)
Minimum flow adjustment

TECHNICAL INFORMATIONS

A: Auxiliary
SR: Semirapid
R: Rapid
MW: Mini-Wok
TC: Triple Crown
Operating voltage
Regulated for gas
Qn
TOT
A: Auxiliary
SR: Semirapid
R: Rapid
MW: Mini-Wok
TC: Triple Crown
Operating voltage
Regulated for gas
Qn
TOT
A: Auxiliary
SR: Semirapid
R: Rapid
MW: Mini-Wok
TC: Triple Crown
Operating voltage
Regulated for gas
Qn
TOT
The appliance should not be removed from the worktop.
Before converting, disconnect the appliance from the power mains and close the gas
supply valve.
Remove the support grid and burner covers with respective crowns.
Replace the existing nozzles for nominal thermal load with corresponding nozzles for
the new gas type and supplied provided (see Nozzle table). In double burners,
adjustment elements are accessible behind the main nozzle protective plate.
After finishing this sequence, replace the old setting label with the new one provided for
the new injectors.
The category with the related types of gas can be used are included in ʺConversion to a
different type of gasʺ table.
Instructions for town (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the control knobs, including the gaskets.
3. Turn the adjustment screw on the side of the tap rod until a regular minimum flame is
obtained:
anti-clockwise to increase the gas flow;
clockwise to reduce the gas flow.
4. Re-assemble the knob and verify burner flame stability (when quickly rotating the hand
from maximum to minimum position the flame must not shut off).
5. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
426150
439193
429254
426152
429253
G20=20mbar
G30=30mbar
7500 W
7800 W
426158 - 453969
426147
453969 - 429255
G30=30mbar
G20=20mbar
7500 W
11300 W
426159
663459 - 663463
220-240 V~ ; 50/60 Hz
G20=20mbar
11300 W
11300 W / 827 g/h
426160
426167
439192
730852
220-240 V~ ; 50/60 Hz
G30=30mbar
11300 W
439422
220-240 V~ ; 50/60 Hz
G20=13mbar
7500 W
G30=50mbar
9
426164 - 426162
426166 - 450420
426153 - 567006
567002
G30=30mbar
G20=20mbar
11300 W
439421
G20=13mbar
7800 W
426149
7500 W
439427
439425
G20=13mbar
7500 W

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis