Prior to set up
Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up.
Note
No modifications may be made to the firing installation. This also
leads to loss of warranty and guarantee.
Floor protection
A base is required (glass, sheet steel or ceramic) if the floor is
combustible (wood, carpet, etc.).
Flue pipe connection
Flue pipes pose a particular source of hazard regarding gas leaks
Q
and fire. Get the advice of an authorised specialist company for
the layout and assembly.
Please observe the corresponding installation guidelines for walls
Q
panelled with wood when connecting your flue pipes to the stove.
Observe the formation of flue gas (atmospheric inversion) and
Q
draughts when the weather is unfavourable.
Infeed of too little combustion air can lead to smoke in the rooms
Q
or to flue gas leaks. Hazardous deposits in the stove and chimney
may also occur.
If flue gas escapes, let the fire burn out and check whether all the
Q
air inlet openings are free and the flue gas pipes and the stove
pipe are clean. If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney.
Stoves type 1 (BA 1):
Suitable for multiple occupancy. (Note the different country
Q
regulations.)
These may only be operated with the combustion chamber door
Q
closed.
The combustion chamber door may only be opened to add fuel
Q
and must then be closed again otherwise other firing installations
connected to the chimney may be endangered.
The combustion chamber door is to be kept closed when the
Q
stove is not in operation.
Fouling of the chimney i.e. deposits of highly inflammable
Q
materials such as soot and tar and subsequently fire in the
chimney may occur if wet fuel is used and operation is damped
too much.
If
this
occurs,
close
Q
regulator,
flaps
-
depending
the
mains
plug
at
Phone the fire brigade and get yourself and other residents out
of harm's way.
Note
on ROOM-AIR DEPENDENT and ROOM-AIR INDEPENDENT
OPERATION:
Your stove has been tested as a room-air independent stove
according to EN 13240 and can be installed as well room-air
dependent and independent.
When installed room-air dependent in combination with room-
air installations (e.g. controlled ventilation and venting systems
(extractors etc.) it must be ensured that the stove and the room
air system are monitored and safeguarded mutually (e.g. via a
differential pressure controller etc.). The combustion air infeed of
approx. 20 m3/h must be ensured.
Please observe the respective local regulations and rules in
consultation with your master chimney sweep. For changes after
the printing of this manual, we can not assume any liability. We
reserve the right to change without notice.