Storage
After they are cleaned and dried, compressed-air breathing apparatuses may be stored in a suitable cabinets or boxes.
Make sure that the apparatus is placed on the support plate and that the straps are not folded.
Compressed-air breathing apparatuses must be stored in a cool place. The storage area must be dry and free of any emission of gas or
fumes. Avoid exposure to direct and significant light or sunlight and keep away from sources of thermal radiation.
The recommended apparatus storage temperature must be between +5°C and +45°C:
For special storage conditions (under outdoor shelters etc.), please contact our technical department.
ACCESSORIES
TESTAIR III electronic inspection bench:
Inspection accessory:
Medium pressure connecting device:
Storage case for the apparatus:
Call horn:

SPARE PARTS

The spare parts of the FENZY X-PRO device are presented using exploded views in the spare parts price list (price and part number),
which is available on request.
SUPPORT AND TRAINING
All HONEYWELL RESPIRATORY SAFETY PRODUCTS apparatuses are designed to allow maintenance by the users, but that requires
a minimum level of skills and the use of appropriate equipment.
Training courses may be organised on the customer's premises or in our own training establishments.
The full programme of training courses for device maintenance is available on request.
HONEYWELL RESPIRATORY SAFETY PRODUCTS markets an electronic inspection bench to guarantee the quality of the work done.
For more information, please contact the HONEYWELL RESPIRATORY SAFETY PRODUCTS technical assistance department.
LIMIT OF MANUFACTURER'S GUARANTEE
In accordance with HONEYWELL RESPIRATORY SAFETY PRODUCTS specifications, checks and maintenance operations must be
performed by personnel qualified and authorised by HONEYWELL RESPIRATORY SAFETY PRODUCTS. Only original inspection
benches, special tools and spare parts may be used. The recommendations relating to the frequency of testing and maintenance
described in these instructions must be followed.
Only apparatuses from HONEYWELL RESPIRATORY SAFETY PRODUCTS with their cylinders, valves and masks are covered by the
CE configuration certification.
As a result, this guarantee does not cover apparatuses used with components other than those supplied or replaced by HONEYWELL
RESPIRATORY SAFETY PRODUCTS.
OPTIONAL
On request, the FENZY AERIS may be fitted with the option 'Medium pressure flexible hose fitted with a self-sealing inlet
connector'.
This hose allows the breathing apparatus to be connected, using the self-sealing quick connector, to a medium pressure source of
breathable air, the minimum flow rate of which must be 500 litres/minute and the pressure must be:
Between 6 and 7.5 bar when the breathing apparatus is fitted with the SA 5000, (Figure 4) or SA 5000 Zenith, (Figure 4).
Between 5 and 8.5 bar when the breathing apparatus is fitted with the SX-PRO. (Figure 5).
Use
The breathing apparatus fitted with this option is used as follows:
Before and after using the breathing apparatus, check that the inlet connector on the flexible hose is clean; if it is dirty, do not use
the apparatus and contact a specialised breathing apparatus maintenance workshop, the manufacturer or distributor.
Loosen the backplate straps as much as possible.
Put the apparatus on your back and pull the ends of the straps until you feel the apparatus hangs comfortably on the shoulders.
Tighten the backplate belt then the chest strap linking the two straps (if this option is fitted).
Put the breathing mask in place (see instructions for using the breathing mask). (Figure 8a)
Check that the breathing mask is sealed (see instructions for using the breathing mask). (Figure 8b)
Do not open the cylinder valve(s) (Figure 8c)
Connect the medium pressure flexible hose to the source of medium pressure breathable air.
Snap the demand valve onto the Air Klic connector of the respiratory mask (see section on demand valve) (Figure 8e)
The breathing apparatus is ready for use.
After using the breathing apparatus, protect the inlet connector of the flexible hose from dirt using a protective cap.