Intended use
The product is exclusively intended for installation in a machine or
system or combination with other components to form a machine or
system. The product may only be commissioned after it has been
installed in the machine/system for which it is intended. Use is
permitted only under the operating conditions and within the
performance limits listed in the technical data. Only use compressed
air as the medium.
The product is technical equipment and is intended for professional
use only.
Intended use includes having read and understood these instructions
completely, especially chapter "Notes on Safety".
Personnel qualifications
All tasks associated with the products require basic mechanical,
electrical, and pneumatic knowledge, as well as knowledge of the
respective technical terms. In order to ensure operational safety,
these tasks may only be carried out by qualified personnel or an
instructed person under the direction of qualified personnel.
Qualified personnel are those who can recognize possible hazards
and institute the appropriate safety measures, due to their
professional training, knowledge, and experience, as well as their
understanding of the relevant conditions pertaining to the work to
be done. Qualified personnel must observe the rules relevant to the
subject area.
General safety instructions
W
Observe the valid local regulations to protect the environment
in the country of use and to avoid workplace accidents.
W
Only use AVENTICS products that are in perfect working order.
W
Examine the product for obvious defects, such as cracks in the
housing or missing screws, caps, or seals.
W
The warranty will not apply if the product is incorrectly
assembled.
W
Do not place any improper mechanical loads on the product
under any circumstances.
W
Product warnings and information must be legible, i.e. not
covered by paint, etc.
Safety instructions related to the product
and technology
W
Lay cables and lines so that they cannot be damaged and no
one can trip over them.
W
Do not operate the product in aggressive ambient air (i.e.
solvent gases).
3

Delivery Contents

The following is included in the delivery contents:
W
1 regulator or filter pressure regulator as per order (optional:
pressure gauge supplied loose)
W
Operating Instructions
4

About This Product

Regulators and filter pressure regulators are components of
maintenance units. Regulators and filter pressure regulators serve
to reduce the applied system pressure to a maximum, controlled
operating pressure. Filter pressure regulators are compact units
and also serve to coarsely filter the compressed air.
5
Assembly, Commissioning,
Operation
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or electrical voltage can lead
to injuries and damage to the product or system components.
O
Make sure that the relevant system part is not under voltage
or pressure before you assemble the product.
O
Protect the system against being switched on.
Sudden surge in pressure during start-up!
If no SSV filling unit is used, the system will suddenly be under
pressure during start-up. This could cause dangerous and
sudden cylinder movements.
O
When starting up a system without an SSV filling valve, make
sure that the cylinders are in their end position. For cylinders
not in the end position, make sure they do not present any
danger.
System is operating under pressure.
Incorrect installation could damage the maintenance unit/
device and cause serious injury.
O
Before start-up, check that all connections, ports, and
maintenance devices have been correctly installed.
Assembling the mounting elements W01 –
W06
O
W01
Observe the figures
1
Mounting the pressure gauge (1-I)
If the pressure gauge is ordered separately, the compression ring
will be supplied as a separate part.
O
Insert the compression ring in the pressure gauge.
O
If the pressure gauge is not used, the blanking screw
must be screwed into the regulator and sealed.
1. Rotate the pressure gauge into the pressure gauge thread until
the compression ring is completely screwed into the thread
(size 14 open-end wrench).
2. Align the pressure gauge by rotating it by a max. 3/4 turn back
or forth.
Max. tightening torque: 7 – 8 Nm.
During commissioning
O
Let the product acclimatize for several hours before
commissioning; otherwise, water may condense in the
housing.
O
Make sure that all electrical and pneumatic connections are
either used or covered. Only commission the product after it
has been completely installed.
2
Setting the pressure
1. Pull hand wheel (a) upwards.
2. Turn hand wheel (a) to set the desired pressure.
3. Press hand wheel (a) downwards.
This relocks the hand wheel.