Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Wiring Connection - McQuay C Serie Installationsanleitung

Vorschau ausblenden Andere Handbücher für C Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
Ø Tube, D
Inch
mm
1/4"
6.35
3/8"
9.52
1/2"
12.70
5/8"
15.88
3/4"
19.05
Pipe Size, mm (in)
6.35 (1/4)
9.53 (3/8)
12.7 (1/2)
15.88 (5/8)
19.05 (3/4)
IMPORTANT:
* These values are for information only, they should be checked and selected to comply with the local and/
or national codes and regulations. They are also subjected to the type of installation and size of
conductors used.
.
Indoor unit
Outdoor unit
Voltage range
Power Supply Cable size*
Number of conductors
Interconnection Cable size*
Number of conductors
Recommended time delay fuse*
5CEY62CR – 5SLY60ER
Indoor Unit
Terminal Block
1
2
3
!
Power Supply
A (mm)
Imperial
Rigid
1.3
0.7
1.6
1.0
1.9
1.3
2.2
1.7
2.5
2.0
Torque, Nm (ft-lb)
18 (13.3)
42 (31.0)
55 (40.6)
65 (48.0)
78 (57.6)

ELECTRICAL WIRING CONNECTION

mm
2
2
mm
A
Interconnection
Cable
Cable
Flare Joint
Indoor Piping
Spanar
5CEY62CR
5SLY60ER
220V – 240V/1Ph/50Hz + N + !
1.5
32
Outdoor Unit
Terminal Block
1
2
3
L
N
!
!
!
The electrical power must be provided with
protection devices (circuit breaker or fuse)
with double pole separation system (phase +
neutral) with minimum contact gap of 3mm.