Follow
the
procedures
"Commissioning" to add RTS control points, RTS sensors
and favourite positions.
7.3 Replacing a lost or broken RTS control
point
This reset deletes all control points, however, it does not
delete the sensors and the favourite position.
Caution! Only switch off the power for the motor to be
reset.
-
Place the roller shutter in the mid-height position.
1)
Cut the power supply for 2 seconds.
2)
Switch the power supply back on for 5 to 15 seconds.
3)
Cut the power supply for 2 seconds.
4)
Switch the power supply back on:
The roller shutter moves for several seconds.
Caution: if the roller shutter is in the upper or lower end limit
position it will move up and down briefly.
5)
Press the PROG button on the new RTS control point
(L) until the roller shutter moves up and down: all RTS
control points are cleared and the new RTS control point
(L) is programmed into the motor.
-
Follow
the
procedures
"Commissioning" to add RTS control points.
8. Technical specifications
Radio frequency
Power supply
Operating temperature
Index protection rating
Maximum number of connected
control points
Maximum number of connected
sensors
Copyright © 2008-2009 Somfy SAS. All rights reserved.
in
the
section
entitled
in
the
section
entitled
Oximo RTS
230 V - 50 Hz
433.42 MHz
230V/50 Hz ~
- 20°C to + 70°C
IP 44
12
3
1
2
OFF
2 seconds.
3
4
OFF
2 seconds.
5
PROG.
L
Oximo RTS
120 V - 60 Hz
433.42 MHz
120V/60 Hz ~
- 4°F to + 158°F
IP 44
12
3
Oximo RTS
ON
10 seconds.
ON
M
K
55